{"product_id":"330905-00-07-10-02-05-bently-nevada-3300-nsv-series-proximity-probes","title":"330905-00-07-10-02-05 Bently Nevada 3300 NSv Series Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330905-00-07-10-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330905\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes, operates as a dedicated hardware component for non-contacting static and dynamic displacement measurements within 3300 NSv System platforms. The hardware registers physical gap distances between the probe tip and target conductive surfaces, outputting proportional voltage variations to monitor structural vibration variables.\u003c\/p\u003e\n\u003ch3\u003ePart Number Option Codes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330905: Main catalog identifier for the 3300 NSv proximity probe assembly with 3\/8-24 UNF thread profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded length designation (0.0 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e07: Overall case length designation (0.7 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length option indicator (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector type selection (miniature coaxial click-loc standard option).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval configuration (multiple hazardous area approvals integrated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330905-00-07-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) typical when paired with compatible Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor driven by Proximitor sensor excitation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 cm x 15.2 cm x 5.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe probe operates via eddy-current probe scaling matrices designed to measure fluid-film bearing clearances and rotor dynamics. Internal transducer calibration profiles generate gap voltage validation values targeting a baseline of -10 VDC during typical midpoint setup configurations. Cross-talk suppression logic functions inside the matched system cabling layout to shield low-level raw voltage inputs from adjacent sensor emissions, ensuring accurate tracking of axial position limits.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1* 330905-00-07-10-02-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1* Coaxial Connector Protective Silicone Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Calibration and Thread Engagement\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the sensor body into the indicator bracket mount until it achieves a minimum of 5 full threads engagement inside the mounting base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the physical insertion depth while measuring output gap voltage values with a digital voltmeter until reaching the target operational center value.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCable Routing and Shield Termination\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the extension cables within dedicated layout trays using insulated cable clamps to block high mechanical strain vectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute coaxial signal pathways inside rigid conduits away from high-voltage motor supply feeds to limit structural electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe system support hot-swap changeout while the monitor rack remains powered?\u003c\/p\u003e\n\u003cp\u003eYes, the sensor element can be disconnected and reconnected under rack excitation power without creating transient component layer failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is target gap voltage validation performed during initial field mounting cycles?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the DC potential across signal ports to track negative voltage variations until reaching target baseline levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical parameters dictate the standard eddy-current probe scaling performance?\u003c\/p\u003e\n\u003cp\u003eThe diameter of the transducer tip relative to the target metallurgic profile directly scales the conversion output ratio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity sensor operate independently without an external active Proximitor block?\u003c\/p\u003e\n\u003cp\u003eNo, the device behaves as a passive inductor array that requires excitation waveforms from an matched receiver unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal cross-talk suppression managed when multiple sensors are mounted close together?\u003c\/p\u003e\n\u003cp\u003eProper layout demands standard target installation gaps between adjacent tips to eliminate radio-frequency field overlap loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat style connector terminates the integrated lead cable on this hardware version?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes a coaxial terminal plug layout configured to click securely into matching system extension line arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of swapping components with non-matched firmware flash compatibility levels?\u003c\/p\u003e\n\u003cp\u003eThe sensor tracks analog changes, but the host receiver module firmware must match the probe type code configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do environmental boundary conditions modify the continuous insulation lifespan?\u003c\/p\u003e\n\u003cp\u003eContinuous usage beyond the maximum specified operating temperature levels causes gradual internal core material failure paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026768056493,"sku":"330905-00-07-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_1f6c0792-85aa-4211-8876-269b3182c21d.jpg?v=1783674280","url":"https:\/\/www.maxwellplc.com\/products\/330905-00-07-10-02-05-bently-nevada-3300-nsv-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}