{"product_id":"330903-00-04-05-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330903-00-04-05-02-00 Bently Nevada 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330903-00-04-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330903\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting shaft vibration and position monitoring across 3300 XL 8 mm platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Metrics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330903\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330903-00-04-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 x 15.0 x 11.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSourced via connected Proximitor Sensor loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Cross-Talk Suppression and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe hardware processes physical displacement parameters using advanced eddy-current probe scaling matrices. To maintain linear signal tracking across full dynamic excursions, field configuration requires strict gap voltage validation (-10 VDC targets) within the baseline measurement zone. This calibration standard ensures precise detection of high-frequency rotor dynamics and transient mechanical anomalies while maintaining internal cross-talk suppression between orthogonal X-Y probe pairs sharing adjacent structural space.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries and Answers\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary system safety restrictions regarding hot-swapping or live decoupling?\u003c\/p\u003e\n\u003cp\u003eA: The probe assembly has no built-in isolating switches; the auxiliary Proximitor Sensor must be powered down before separating the coaxial extension cable to prevent signal saturation or damage to the monitoring channel backplane interface.\u003c\/p\u003e\n\u003cp\u003eQ: How does mismatched total cable length modify the electrical characteristics of the loop?\u003c\/p\u003e\n\u003cp\u003eA: Interfacing the probe with a cable length that deviates from the factory-calibrated 5.0 meter or 9.0 meter hardware specifications changes the baseline loop capacitance, causing errors in eddy-current probe scaling accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What is the isolation requirement for the probe shield assembly?\u003c\/p\u003e\n\u003cp\u003eA: The internal coaxial outer shield must remain completely isolated from the machine housing. Ground loops must be suppressed by grounding the shield solely at the instrument rack terminal bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Torque Limits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure correct thread tracking during casing insertion to avoid physical stress or cracking of the 8 mm tip potting compound.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a calibrated multi-meter to check the gap voltage validation (-10 VDC targets) prior to locking down the physical jam nuts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Lead Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall specialized high-temperature insulating sleeves over all terminal connections to block accidental contact with the machine chassis ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute all sensor extension leads through dedicated, isolated conduit runs to separate low-voltage measurement loops from heavy industrial power infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEquipment Procurement Scope\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330903-00-04-05-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Locknut Hardware Packet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal Protection Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDispatch and Packaging Protocol\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, with global logistics managed by DHL\/FEDEX\/UPS. All shipments utilize protective anti-static industrial packaging to isolate the precision sensor components from environmental moisture and electrostatic discharge during movement.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518865498285,"sku":"330903-00-04-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330903-00-04-05-02-00-3300-xl-8-mm-proximity-probes-qf0wp3upnjx.jpg?v=1766980502","url":"https:\/\/www.maxwellplc.com\/products\/330903-00-04-05-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}