{"product_id":"330901-22-40-10-01-05-bently-nevada-proximity-probes-3300-nsv-series","title":"330901-22-40-10-01-05 Bently Nevada Proximity Probes 3300 NSv Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330901-22-40-10-01-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for high-frequency displacement measurement within 3300 NSv transducer system platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330901: 3300 NSv 5 mm proximity probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e22: 1\/4-28 UNF thread configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40: 40 mm unthreaded case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 10 mm total case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: Miniature coaxial connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330901-22-40-10-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 15.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDependent on Proximitor loop impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Eddy-Current Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv probe functions via eddy-current induction to detect target displacement. Reliable rotor dynamics analysis requires precise gap voltage validation; the transducer system is calibrated to a target of -10 VDC at the center of the linear operating range. Signal integrity relies on effective cross-talk suppression, achieved by maintaining defined physical spacing between probes to prevent RF field interference. Users must ensure that probe scaling is matched to the specific target material, typically AISI 4140 steel, to maintain displacement measurement linearity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330901-22-40-10-01-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated miniature coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStainless steel locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector protection cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the probe into a rigid, non-ferrous, grounded bracket to ensure mechanical stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Use a feeler gauge to establish the physical gap; verify the output voltage at the Proximitor terminal using a high-impedance multimeter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate the coaxial cable shield at the Proximitor sensor end only to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use only factory-supplied shielded coaxial cables. Route through grounded conduit and avoid bending radii of less than 25 mm to prevent impedance shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the standard scale factor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system is calibrated for a scale factor of 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable gap voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstability is typically caused by electrical ground loops, damaged coaxial shielding, or external electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should calibration be verified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCalibration verification is recommended annually or after any mechanical maintenance affecting the probe-to-target air gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the probe tip material?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv probe tip is constructed from polyphenylene sulfide (PPS) to withstand high-temperature industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is probe health tested?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHealth is determined by verifying coaxial continuity, checking insulation resistance, and confirming DC gap voltage linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe be used in hazardous zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"05\" suffix indicates specific agency approvals. Verify site-specific hazardous area drawings before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the coaxial connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe miniature coaxial connector allows for signal transmission while maintaining the low-capacitance profile required by the 3300 NSv system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is AISI 4140 steel the calibration target?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe eddy-current response is material-dependent; AISI 4140 steel provides a predictable, industry-standard reference for displacement linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518844657837,"sku":"330901-22-40-10-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330901-22-40-10-01-05-3300-nsv-proximity-probes-zgky153vxqg.jpg?v=1766980258","url":"https:\/\/www.maxwellplc.com\/products\/330901-22-40-10-01-05-bently-nevada-proximity-probes-3300-nsv-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}