{"product_id":"330901-00-70-10-02-05-bently-nevada-3300-nsv-proximity-probes","title":"330901-00-70-10-02-05 Bently Nevada 3300 NSv Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330901-00-70-10-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3300 NSv Machinery Protection Systems. It transforms mechanical distance deviations into equivalent electrical voltage variables directly processed by local continuous monitoring instrumentation.\u003c\/p\u003e\n\u003ch3\u003eOption Code Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330901\u003c\/strong\u003e: 3300 NSv 3\/8-24 UNF thread proximity probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option (0.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-70\u003c\/strong\u003e: Overall case length option (7.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Total length option (1.0 m \/ 3.3 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Miniature coaxial clickloc connector with connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (Multiple approvals, ATEX \/ IECEx intrinsic safety and non-incendive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330901-00-70-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 15.0 cm x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.52 mm (60 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer component driven by Proximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe probe functions via eddy-current probe scaling tuned precisely to a 7.87 V\/mm scale factor. Operational field setups require precise gap voltage validation with -10 VDC targets representing the middle of the linear calibrated window. For high-density rotor dynamics monitoring, the physical layout demands strict adherence to minimum side-clearance spacing boundaries to ensure signal cross-talk suppression. Incorrect spacing distorts the magnetic flux lines generated by the 5 mm tip, leading to false voltage variations.\u003c\/p\u003e\n\u003ch3\u003eKit Packaging Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330901-00-70-10-02-05 eddy-current transducer probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory-installed miniature coaxial clickloc male connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Removable external silicone connector protector sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Material certificate and multi-language compliance manual sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement\u003c\/strong\u003e: Ensure free hand-rotation during thread insertion into the mounting bracket; mechanical binding indicates thread misalignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibrations\u003c\/strong\u003e: Monitor the active DC voltage at the Proximitor sensor output during adjustment until reaching the target value of -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing Dispositions\u003c\/strong\u003e: Secure the flexible coaxial lead through rigid conduit or internal cable trays to avoid continuous mechanical friction or flexing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Isolation\u003c\/strong\u003e: Terminate the outer coaxial shield layer solely at the Proximitor sensor chassis block to counteract structural ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Dispatch Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransit Frame: 2-7 days when payment finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistribution Channels: Dispatched internationally through premium express carriers DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Protection: Packaged in anti-static industrial packaging featuring shock-absorbent multi-layer containment enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Answers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard target gap voltage required during probe positioning?\u003c\/p\u003e\n\u003cp\u003eThe target setup requires adjusting the gap until the Proximitor sensor output reads -10 VDC. This places the static probe tip position exactly in the center of the calibrated linear displacement spectrum for AISI 4140 steel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific probe model be hot-swapped while the machinery monitor is energized?\u003c\/p\u003e\n\u003cp\u003eYes, the passive transducer can be disconnected and reconnected at the Proximitor link without powering down the main 3500 rack system. However, sudden signal drops will trigger local alarm loops if bypass interlocks are not engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does changing the targeted shaft material change the probe output scaling?\u003c\/p\u003e\n\u003cp\u003eThe eddy-current calibration is engineered for AISI 4140 steel. Target materials with alternative magnetic permeability alter the nominal scale factor, demanding recalibration or correction scaling inside the processing monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the -02 option connector protector component?\u003c\/p\u003e\n\u003cp\u003eThe option provides an outer silicone sleeve that seals the connection point between the probe lead and extension cable, isolating the terminal from fluid contaminants, moisture, and corrosive industrial atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external power supply source required for this hardware module?\u003c\/p\u003e\n\u003cp\u003eNo, the probe is completely passive. It relies entirely on the high-frequency RF signal supplied via the interconnecting extension cable from the matching 3300 NSv Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat minimum side clearance is demanded to maintain cross-talk suppression?\u003c\/p\u003e\n\u003cp\u003eTo prevent flux field interaction, maintain a minimum clear radius of three probe tip diameters from any adjacent structural metals not representing the verified dynamic target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to system performance if the total length limits are exceeded?\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system demands a fixed total electrical length of either 5.0 or 7.0 meters. Using an unmatched extension cable shifts the system impedance, distorting the scale factor and ruining calibration linearities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operational temperature threshold for the probe tip assembly?\u003c\/p\u003e\n\u003cp\u003eThe tip and integral cable assembly are structurally rated to sustain continuous exposure within an environmental temperature window ranging from -35 deg C up to a maximum limit of +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518863401133,"sku":"330901-00-70-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330901-00-70-10-02-05-3300-nsv-proximity-probes-wzmqtscborl.jpg?v=1766980433","url":"https:\/\/www.maxwellplc.com\/products\/330901-00-70-10-02-05-bently-nevada-3300-nsv-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}