{"product_id":"330901-00-12-70-01-05-bently-nevada-proximity-probes-3300-nsv","title":"330901-00-12-70-01-05 Bently Nevada Proximity Probes 3300 NSv","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330901-00-12-70-01-05\u003c\/strong\u003e is a highly specialized \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e designed for critical machinery protection systems (MPS) and continuous turbomachinery condition monitoring. The 3300 NSv (Near Surface Void) transducer platform is intentionally engineered for applications where standard 8 mm proximity probes are physically too large, or where the targeted shaft diameter or observed viewing counterbore is constrained. Operating on non-contacting eddy current principles, this probe delivers precise static and dynamic displacement data, making it exceptional for tracking radial shaft vibration, axial thrust position, and high-frequency tachometer\/phase reference (Keyphasor) inputs.\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system offers a dependable linear operating range of \u003cstrong\u003e1.0 mm (40 mils)\u003c\/strong\u003e. This restricted linear envelope provides enhanced sensitivity when looking at small targets, such as narrow shaft collars or precision timing slots. The sensor excels at maintaining a flat thermal response across fluctuating internal machinery temperatures, providing excellent repeatability where minor calibration deviations could trip a critical asset. By minimizing thermal drift, this sensor prevents false trips while maintaining absolute machine protection.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features an English fractional 3\/8-24 UNF threaded body with a 0.0-inch unthreaded section (fully threaded), a compact 1.2-inch overall case length, a 7.0-meter (23.0 feet) integrated coaxial cable protected by a flexible stainless steel fluid-resistant armor sleeve, and a gold-plated miniature coaxial ClickLoc connector with a pre-installed connector protector. Equipped with the comprehensive \u003cstrong\u003e05 Multiple Approvals\u003c\/strong\u003e package, it complies with global intrinsic safety (IS) and non-incendive design rules, making it suitable for immediate deployment across hazardous industrial locations worldwide.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMechanical \u0026amp; Electrical Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Specification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Business)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330901-00-12-70-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Contacting Eddy Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 mm (0.197 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Type and Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish Fractional 3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length (00)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 inches (Fully threaded body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 inches (30.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length (70)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable \/ Armor Selection (01)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, fluid-resistant armored cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector (01)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-installed connector protector included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals (05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (ATEX, IECEx, CSA, Class I Div 1 \u0026amp; 2, Zone 0\/1\/2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) nominal range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when paired with matching loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Calibration Target\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 Electric Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Insulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS) with specialized overmolding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.2 N·m (100 in·lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Cable Pull Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e222 N (50 lb) maximum force (Case-to-lead anchor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Fluid Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully sealed against water, steam, synthetic lubes, and turbine oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.0 * 16.5 * 4.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe model string \u003cstrong\u003e330901-00-12-70-01-05\u003c\/strong\u003e represents a precise selection from the Bently Nevada 3300 NSv catalog, mapping out the physical parameters required for exact mechanical field drop-ins:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330901\u003c\/strong\u003e: The foundational base model number for the 3300 NSv Proximity Probe configured with an English fractional thread profile (3\/8-24 UNF).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: \u003cstrong\u003eUnthreaded Length Option.\u003c\/strong\u003e Specifies a 0.0-inch unthreaded section. The sensor housing is fully threaded down to the tip transition, allowing maximum depth adjustment inside tight mounting blocks or brackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12\u003c\/strong\u003e: \u003cstrong\u003eOverall Case Length Option.\u003c\/strong\u003e Designates a 1.2-inch total case length, providing a ultra-low profile body ideal for shallow entry holes or direct internal installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70\u003c\/strong\u003e: \u003cstrong\u003eTotal Length Option.\u003c\/strong\u003e Dictates a 7.0-meter (23.0 feet) integrated cable lead, which allows direct routing from the bearing cap straight out to the external field junction box without the need for an intermediate extension cable connection inside the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: \u003cstrong\u003eConnector and Cable Type Option.\u003c\/strong\u003e Selects a miniature coaxial ClickLoc connector protected by a flexible stainless steel armor sleeve, shielding the internal coaxial wire from mechanical damage and harsh industrial fluids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: \u003cstrong\u003eAgency Approval Option.\u003c\/strong\u003e Multiple Approvals certification package, covering international intrinsic safety (IS) and non-incendive rules under ATEX, IECEx, and North American CSA frameworks for Zone 0, Zone 1, Zone 2, and Class I Division 1\/2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe 330901-00-12-70-01-05 proximity probe is critical for assessing machine health across continuous process industries, particularly where narrow clearances or tiny target profiles restrict the deployment of standard 8 mm sensors:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall-Diameter Shaft Vibration:\u003c\/strong\u003e Installed on small-scale centrifugal pumps, high-speed fans, and turbochargers where the shaft diameter is less than 50 mm (2.0 inches), preventing the target curvature errors common with larger probe tips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadial Positioning in Tight Housings:\u003c\/strong\u003e Used in compact industrial gearboxes and internal fluid-film bearings where minimal physical envelope clearance prevents deep mechanical cross-sections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Tachometer \u0026amp; Keyphasor Systems:\u003c\/strong\u003e Monitors precision-machined speed wheels, gear teeth, or narrow keyways to capture high-frequency trigger events for phase angle tracking and continuous RPM telemetry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAeroderivative Gas Turbines:\u003c\/strong\u003e Deployed within the complex internal auxiliary bearing housings of aviation-derived gas generators to track shaft dynamic behavior under high vibration and thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eTo satisfy rigorous API 670 operational design parameters, the 330901 proximity probe must be matched with its complementary signal conditioning components to complete the circuit loop:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Proximitor Sensor Connection:\u003c\/strong\u003e Connects directly into a matching \u003cstrong\u003e3300 NSv Proximitor Sensor\u003c\/strong\u003e (Model 330980). Because the integrated probe cable length is 7.0 meters, it matches directly with a 7.0-meter Proximitor model \u003ci\u003ewithout\u003c\/i\u003e requiring an intermediate extension cable, establishing a true, low-noise single-cable loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Standard 3300 XL Components:\u003c\/strong\u003e This probe is entirely incompatible with standard 3300 XL 8 mm Proximitor sensors or extension cables. Mixing the NSv probe with 3300 XL components will severely distort the RF oscillation field and corrupt the nominal scale factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Monitors:\u003c\/strong\u003e Links via terminal blocks directly to the backplane inputs of the \u003cstrong\u003eBently Nevada 3500\/42M Proximitor Seismic Monitor\u003c\/strong\u003e module, the 3500\/25 Keyphasor card, or distributed Orbit60 machine protection architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Alignment \u0026amp; Gapping Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Surface Quality:\u003c\/strong\u003e Ensure the shaft measurement path is completely free of grinding patterns, score marks, or metallurgic variations. A surface finish of 0.8 micrometers (32 microinches) Ra or better prevents artificial electrical runout signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetting the Operating Gap:\u003c\/strong\u003e Thread the probe into its mounting bracket while checking the DC bias voltage at the Proximitor Sensor's terminal strip or buffered output port. Turn the body until the meter shows \u003cstrong\u003e-10.0 Vdc\u003c\/strong\u003e, marking the precise midpoint of the 1.0 mm (40 mils) linear tracking envelope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Clearance Requirements:\u003c\/strong\u003e Because of the smaller 5 mm tip diameter, the NSv series requires a significantly smaller viewing counterbore than 8 mm probes. Provide a minimum counterbore diameter of only 19 mm (0.75 inches) surrounding the tip to prevent side-view metal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreventing Sensor Cross-Talk:\u003c\/strong\u003e When installing two sensors in an X-Y configuration on the same bearing face, separate the probe tips by a minimum of 25 mm (1.0 inch). This prevents overlapping RF fields from causing cross-talk noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque and Locking Safety:\u003c\/strong\u003e Once the -10.0 Vdc gap voltage is confirmed, secure the position by tightening the 3\/8-24 UNF hex locknut. Do not exceed the structural limit of \u003cstrong\u003e11.2 N·m (100 in·lb)\u003c\/strong\u003e. Run lockwire through the predrilled nut holes to secure the assembly against continuous shaft frequency vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for Constrained Geometry:\u003c\/strong\u003e Small 5.0 mm tip diameter allows for highly accurate data collection on tiny targets, thin thrust collars, and narrow shaft surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Armor Shielding:\u003c\/strong\u003e The flexible stainless steel conduit armor prevents physical cutting, abrasion, and degradation from constant exposure to synthetic lubes and hot turbine oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEliminates Intermediate Connections:\u003c\/strong\u003e The extended 7.0-meter integrated length allows for a direct path from the machine casing to the junction box, minimizing potential connection failure points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool-Less ClickLoc Connectors:\u003c\/strong\u003e Features gold-plated brass coaxial connectors that engage with a positive click. This design resists terminal corrosion and vibration detachment without requiring special crimping tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent Thermal Performance:\u003c\/strong\u003e Designed to exhibit minimal scale factor drift across its full temperature operating profile, ensuring true measurements during extreme turbine startups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Ordering Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Specifications Breakdown\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStock Status \u0026amp; Procurement\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330901-00-12-70-01-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, 3\/8-24 UNF, Fully Threaded, 1.2in Case, 7.0m Armored Cable, Connector Protector, Multi-Approvals Certified\u003c\/td\u003e\n\u003ctd\u003eAvailable for Global Express Shipping \/ RFQ Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ci\u003eProcurement Note: This 7.0-meter configuration is designed for direct hookup to a 7.0m Proximitor Sensor. Ensure your inventory or request specifies a matching 3300 NSv 7.0m Proximitor to avoid system loop errors.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003eLogistics and Shipping\u003c\/h3\u003e\n\u003cp\u003eTo preserve precision hardware calibration during global transport, all products are handled with industry-standard instrument packing steps:\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Packaging Protocol:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery Bently Nevada 330901 probe is sealed inside an \u003cstrong\u003eanti-static industrial packaging shield\u003c\/strong\u003e to isolate the internal eddy-current components from static discharge hazards. The sensor head and its flexible armored cable are cradled within custom-cut, high-density shock protection foam liners inside a heavy-walled corrugated structural shell. This eliminates the risk of impact crimping, connector flattening, or drop damage during long-distance international air or sea cargo shipping.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use a 330901-00-12-70-01-05 probe with a separate 4.0-meter extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. This probe features an integrated 7.0-meter cable designed to connect directly into a 7.0m 3300 NSv Proximitor Sensor. Adding an extension cable will alter the system's total electrical length, disrupting tuning and invalidating the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy should I choose a 3300 NSv probe over a standard 3300 XL 8 mm probe?\u003c\/p\u003e\n\u003cp\u003eThe NSv probe is designed for restricted physical spaces. It uses a smaller 5 mm tip, allows for a narrower target area, and requires a smaller mounting counterbore diameter, making it ideal for tight bearing housings or small-diameter shafts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the \"01\" option for the cable\/armor selection indicate?\u003c\/p\u003e\n\u003cp\u003eThe \"01\" option indicates that the integrated coaxial cable is wrapped in flexible stainless steel armor for robust physical protection, and it includes a factory-installed connector protector sleeve to shield the ClickLoc junction from oil contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal output scale factor of this 3300 NSv system?\u003c\/p\u003e\n\u003cp\u003eThe nominal scale factor is 7.87 V\/mm (200 mV\/mil). This means that every 1 mil (0.001 inches) of shaft displacement produces a clean, measurable 200 mV change in the DC voltage output from the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can I tell if an installed 330901 probe has an internal short circuit?\u003c\/p\u003e\n\u003cp\u003eDisconnect the probe and use a digital multimeter to measure resistance between the center pin and outer shield of the ClickLoc connector. A standard 7.0m NSv probe reads roughly 7.0 Ω to 12.0 Ω. A reading near 0 Ω indicates a short circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe require regular calibration fields adjustments?\u003c\/p\u003e\n\u003cp\u003eNo. The Bently Nevada 3300 NSv platform components are built to be completely interchangeable. As long as you maintain the factory-specified loop length and target material (AISI 4140), components can be hot-swapped without loop recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the targeted shaft is made of stainless steel instead of 4140 steel?\u003c\/p\u003e\n\u003cp\u003eTargeting stainless steel will change the sensor's eddy current response, altering the output scale factor. For non-4140 target materials, you must use a custom-calibrated Proximitor or apply specific electronic correction factors in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the \"05\" approval option certified for hazardous industrial installations?\u003c\/p\u003e\n\u003cp\u003eYes. The \"05\" multiple approvals option provides intrinsic safety (IS) and non-incendive ratings under ATEX, IECEx, and CSA frameworks, making the probe safe for use in Zone 0, Zone 1, Zone 2, and Class I Division 1 or 2 areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518847639725,"sku":"330901-00-12-70-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330901-00-12-70-01-05-3300-nsv-proximity-probes-vte2122l5cy.jpg?v=1766980352","url":"https:\/\/www.maxwellplc.com\/products\/330901-00-12-70-01-05-bently-nevada-proximity-probes-3300-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}