{"product_id":"330881-28-00-125-00-02-bently-nevada-3300-xl-series-proxpac-xl-proximity-transducer","title":"330881-28-00-125-00-02 Bently Nevada 3300 XL Series PROXPAC XL Proximity Transducer","description":"\u003cp\u003ehe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-00-125-00-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROXPAC XL Proximity Transducer\u003c\/strong\u003e, operates as a dedicated hardware component for high-precision vibration and shaft position monitoring within industrial rotating machinery platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe assembly configuration is defined by the following specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881: Base model designation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e28: Housing and material configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Standoff adapter option (None)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e125: Probe length (125 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Interface and connector configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-00-125-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.44 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.02 cm x 12.00 cm x 9.14 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial standard range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType 4X \/ IP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROXPAC XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem utilizes an integrated 8 mm eddy-current probe for non-contacting measurements. To ensure signal accuracy, the system requires precise eddy-current probe scaling within the TSI software interface. Operators must perform gap voltage validation, targeting -10 VDC at the linear range center to maintain system linearity. The PPS housing, reinforced with conductive fibers, provides inherent electrostatic charge dissipation, which minimizes signal noise in high-speed rotating machinery applications where rotor dynamics are critical.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330881-28-00-125-00-02 PROXPAC XL Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Plugs for unused conduit entries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Mounting washers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation and installation guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Integrity: Verify the IP66\/Type 4X seal integrity during installation to prevent environmental ingress in severe industrial conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Stability: Secure the transducer housing using the provided hardware; ensure there is no mechanical resonance between the housing and the machine frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Utilize the conductive properties of the PPS housing to maintain a path for electrostatic dissipation; ensure adequate bonding to the machine case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Management: Route output signals through shielded pathways to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the advantage of the PPS housing? Polyphenylene Sulfide offers superior mechanical strength and chemical resistance compared to traditional steel\/aluminum housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this transducer support hot-swapping? No, electrical connections must be isolated before removing the transducer from the monitor circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 8 mm probe interchangeable? The probe is factory-integrated into the PROXPAC XL assembly and is not designed for field replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the gap voltage? Access the Proximitor output terminals and use a high-impedance voltmeter to confirm the -10 VDC target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan it be used in washdown areas? Yes, the IP66 rating confirms suitability for environments exposed to dust and water spray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of the conductive fibers in the housing? They assist in managing electrostatic buildup, reducing the risk of discharge-induced signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the plugs and washers required for all installations? The plugs must be installed in any unused conduit ports to maintain the IP66 rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this with legacy 3300 systems? The PROXPAC XL is designed for integration into modern 3300 XL monitoring platforms; verify compatibility with monitor channel card firmware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518838726829,"sku":"330881-28-00-125-00-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-00-125-00-02-proxpac-xl-proximity-transducer-ututn0bxyhi.jpg?v=1766980138","url":"https:\/\/www.maxwellplc.com\/products\/330881-28-00-125-00-02-bently-nevada-3300-xl-series-proxpac-xl-proximity-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}