{"product_id":"330876-02-10-00-00-bently-nevada-proximity-probes-3300-xl-series","title":"330876-02-10-00-00 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330876-02-10-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330876\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting displacement measurement across 3300 XL Series platforms. The hardware measures high-amplitude static and dynamic gaps between the 50 mm tip face and a target surface, tracking high-frequency eddy-current parameter transformations generated by the proximity sensor assembly.\u003c\/p\u003e\n\u003ch3\u003eOption Options and Nomenclature\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330876: Base hardware reference identifier for the 3300 XL 50 mm proximity probe system component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Probe case type option specifying an M14 x 1.5 metric mounting thread pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length configuration assigning a 1.0 meter (3.3 feet) integrated lead construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Armor configuration option detailing a high-temperature FluidLoc cable without steel weave layering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Certification approval matrix selecting standard production documentation with no agency approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Metrics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330876-02-10-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Housing Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM14 x 1.5 metric threads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 meter (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Armor Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Temperature FluidLoc Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification Layer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor driven via high-frequency excitation from paired Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 cm x 6.0 cm x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe large 50 mm coil head dictates a wide magnetic field spread, adjusting the eddy-current probe scaling metrics to linearize tracking across broad displacement spans. Managing dynamic rotor dynamics within low-frequency or high-displacement environments demands correct field calibration. Field engineers execute gap voltage validation procedures referencing a standard -10 VDC targets configuration, verifying that the mechanical installation alignment matches the exact center point of the linear system window while external shield properties deliver proper cross-talk suppression against adjacent sensor interference loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 * 330876-02-10-00-00 Proximity Probe Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 * Coaxial Connector Insulator Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Instructions\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation and Thread Engagement\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHand-thread the M14 x 1.5 housing into the custom machine bracket, confirming no less than 5 full threads of engagement before locking down the hardware position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the sensor positioning relative to the shaft face until the linked diagnostic voltmeter measures the target initial bias voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCabling Run and Shield Terminal Integration\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 1.0 meter FluidLoc cable layout through high-clearance flexible conduits, separating the wire run from areas prone to mechanical pinching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAttach the outer shielding link directly to the field termination block terminal, verifying isolation from intermediate structural machine grounding loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swap removal of the sensor line permitted while the matching proximity transmitter card remains active?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware allows hot-swap isolation and line reconnection without generating diagnostic errors across the internal bus system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific issue occurs if the target piece has a face dimension smaller than the 50 mm tip?\u003c\/p\u003e\n\u003cp\u003eSmaller targets alter the eddy-current probe scaling line, which reduces calibration accuracy and creates measurement distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the field gap voltage validation verified on a standard 3300 XL loop setup?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the gap via the buffer terminal port using a high-impedance multimeter, aiming for a -10 VDC baseline value.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this FluidLoc cable structure protect against aggressive process fluids or high humidity?\u003c\/p\u003e\n\u003cp\u003eYes, the high-temperature FluidLoc structure contains internal blocks designed to stop oil or moisture tracking through the wire jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is cross-talk suppression an important parameter for these large 50 mm elements?\u003c\/p\u003e\n\u003cp\u003eThe broad electromagnetic field can bleed into adjacent sensors if they are mounted closer than the minimum required separation distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the displacement tracking loop if an extension cable of incorrect length is added?\u003c\/p\u003e\n\u003cp\u003eAdding wrong extension lengths shifts the loop resonance parameters, which invalidates the calibration slope of the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the upper operating temperature limit for the main 50 mm sensing head?\u003c\/p\u003e\n\u003cp\u003eThe probe head assembly maintains physical and mechanical properties over an operating range up to +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external power source directly attached to the M14 threaded sensor housing?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive sensing coil that receives RF power from the matched Proximitor unit via the coaxial connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026752753837,"sku":"330876-02-10-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--1_da03ff7c-5f53-46ca-8805-b4732b53b8e8.jpg?v=1783666020","url":"https:\/\/www.maxwellplc.com\/products\/330876-02-10-00-00-bently-nevada-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}