{"product_id":"330854-080-24-cn-bently-nevada-proximity-probes-3300-xl-series","title":"330854-080-24-CN Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330854-080-24-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330854\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute non-contact displacement signal routing across 3300 or 3500 Turbine Supervisory Instrumentation (TSI) platforms. The hardware maintains impedance-matched electrical continuity between a 25 mm proximity probe and an external Proximitor sensor, enabling high-range differential expansion and rotor position tracking.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Model (330854):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length Option (080):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.0 meters (26.2 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type Option (24):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh Temperature FluidLoc cable variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option (CN):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA, ATEX, and IECEx hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330854-080-24-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 x 18 x 2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive coaxial transmission path with zero nominal current draw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc moisture-blocking construction\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Component Matching\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 25 mm Proximity Transducer systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330854-080-24-CN extension cable is specifically manufactured with strict physical parameter tolerances to control total loop capacitance and inductance. This precise impedance tuning ensures that the factory eddy-current probe scaling remains linear across the wide operating envelope of the 25 mm transducer system. The internal coaxial shielding parameters are optimized for cross-talk suppression, preventing external radio frequency fields or adjacent high-voltage machinery cables from inducing noise into the sensor circuit, maintaining clear signal pathing for tracking rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eHardware Interfacing FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 8.0 meter extension cable be paired with an unarmored 1.0 meter 25 mm proximity probe?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The combined electrical length of the probe and extension cable must match the required driver hardware configuration exactly. Joining an 8.0 meter extension cable to a 1.0 meter probe forms the standard 9.0 meter tuned loop needed to validate factory eddy-current probe scaling.\u003c\/p\u003e\n\u003cp\u003eQ: What physical protection layer does the FluidLoc option (24) provide over standard cables?\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc cable configuration uses a specialized internal sealing structure that prevents moisture, oil, or chemical contaminants from migrating through the core of the cable by capillary action. This blocks moisture intrusion from reaching the internal terminals even if the outer protective sheath is compromised.\u003c\/p\u003e\n\u003cp\u003eQ: Does installing this cable require manual field loop calibration or component matching?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 XL series components are engineered for complete interchangeability. As long as the correct 9.0 meter system configuration length is maintained, the hardware eliminates the need for manual bench calibration or component matching during field replacement.\u003c\/p\u003e\n\u003ch3\u003eField Interfacing Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Joint Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClean the miniature coaxial ClickLoc interfaces before locking them together. Once engaged, pull the clear insulation sleeve completely over the junction to eliminate structural frame ground paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Routing Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the cable along the internal machine brackets ensuring the layout does not bend past a minimum radius of 25.4 mm (1.0 inch) to prevent structural damage to the inner conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGround the outer instrumentation shielding layer at the monitor rack panel terminal strip only. Let the field end of the shield float to prevent ground loop currents from destabilizing gap voltage validation tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRun the extension cable inside a dedicated, isolated conduit system. Avoid running the high-frequency sensor signal line parallel to high-voltage power lines or variable speed drive output lines to maintain cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Check Elements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Line Components:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne Bently Nevada 330854-080-24-CN 8.0 meter FluidLoc extension cable, silicone connector protection sleeves, and physical registration paperwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Optional Additions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity probe sensors, DIN-rail mounting base plates, and silicon environmental sealing boots must be ordered as distinct lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Configurations and Logistics Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurnaround Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, routed internationally via prioritized express transit channels including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Protection Profiling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSealed in heavy-duty anti-static industrial packaging and shipped inside protective, padded compartments to prevent kinking or stress fractures along the 8.0 meter coaxial path during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026887692461,"sku":"330854-080-24-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330854-080-25-00-extension-cable-jlp2hkctwb0.jpg?v=1766979472","url":"https:\/\/www.maxwellplc.com\/products\/330854-080-24-cn-bently-nevada-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}