{"product_id":"330730-080-03-00-bently-nevada-extension-cable-3300-xl-series","title":"330730-080-03-00 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330730-080-03-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between 11 mm proximity probes and Proximitor sensors within 3300 XL monitoring platforms. This cable maintains the electrical path for high-frequency radio signals required to capture non-contacting vibration and position data.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Analysis\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330730: 3300 XL 11 mm Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e080: Cable Length (8.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Connector Type (Miniature ClickLoc with connector protector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency Approval (Not required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330730-080-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Integrity \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm system is engineered for applications requiring increased linear range compared to 8 mm systems. This extension cable is a calibrated component of the resonant circuit. Achieving high-fidelity rotor dynamics analysis requires strict gap voltage validation at -10 VDC at the monitor output. Cross-talk suppression is maintained through triple-shielded coaxial construction, which isolates the 1 MHz carrier signal from environmental electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330730-080-03-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 38 mm to preserve the coaxial geometry and impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Routing: Install within grounded metallic conduit to provide shielding against high-voltage electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement: Fully seat the ClickLoc connection until a mechanical click occurs; secure the connector protector to seal the interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Sealing: Apply protectors to both probe and sensor coupling points to prevent moisture ingress in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the signal common remains isolated from the machine chassis to avoid the introduction of ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Index\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are 11 mm extension cables compatible with 8 mm probes?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 XL 11 mm system is specifically tuned for the inductance of 11 mm probes; mixing components will cause significant measurement non-linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be shortened if it is too long?\u003c\/p\u003e\n\u003cp\u003eA: No. The system is calibrated for a specific total length. Altering the length changes the resonant frequency and amplitude, rendering measurements invalid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the benefit of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: It provides a secure, vibration-resistant connection that maintains consistent electrical contact and shielding integrity in high-vibration machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I test the cable for electrical integrity?\u003c\/p\u003e\n\u003cp\u003eA: Use a digital multimeter to check continuity between the center conductor pins and verify isolation between the center pin and outer shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable require specific hazardous area approval?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility with hazardous zones depends on the system installation design; always refer to the specific agency control drawings for the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a signal fault?\u003c\/p\u003e\n\u003cp\u003eA: A fault typically manifests as a stable -24 VDC or 0 VDC reading at the monitor, indicating a broken center conductor or a short to the shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I splice the cable using standard RF connectors?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing introduces impedance discontinuities that cause signal reflections, resulting in inaccurate vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How often should connections be inspected?\u003c\/p\u003e\n\u003cp\u003eA: Inspect during major machine turnarounds to ensure connectors remain clean, dry, and securely fastened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518834401453,"sku":"330730-080-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330730-080-03-00-3300-xl-11-mm-extension-cable-od4m4mcjqrd.jpg?v=1766979975","url":"https:\/\/www.maxwellplc.com\/products\/330730-080-03-00-bently-nevada-extension-cable-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}