{"product_id":"330730-080-02-00-bently-nevada-3300-xl-extension-cable","title":"330730-080-02-00 Bently Nevada 3300 XL Extension Cable","description":"\u003cp\u003eConfigured for high-frequency signal transmission in 3300 XL monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330730-080-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330730-080-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical electrical continuity between the proximity probe and the Proximitor sensor.\u003c\/p\u003e\n\u003ch3\u003eSuffix Component Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330730-080-02-00 part number indicates the following hardware configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330730: 3300 XL Extension Cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e080: 8.0 meters total system length requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector assembly option with protective components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No agency approval options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330730-080-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mm x 300 mm x 80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance Matched)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system performance is predicated on maintaining a precise 75 Ohm impedance path across the entire transducer loop. Achieving accurate rotor dynamics data requires consistent eddy-current probe scaling; therefore, the total cable length must match the Proximitor calibration settings. Gap voltage validation (-10 VDC targets) is performed at the Proximitor terminal to ensure the system is operating within its linear sensing range. Additionally, cross-talk suppression is maintained by utilizing high-quality coaxial shielding which must remain continuous, ensuring that high-frequency carrier signals are protected from induced electromagnetic interference in the industrial environment.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330730-080-02-00 Extension Cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ClickLoc connector interface kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective connector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Maintain a minimum static bend radius of 25 mm. Exceeding this limit will alter the characteristic impedance of the coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Mating\u003c\/strong\u003e: Hand-tighten all ClickLoc connections. Do not use external tools to prevent damage to the internal seals and contact pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the cable shield is terminated at the monitoring system's common ground point to eliminate potential ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e: Use cable ties or clamps to secure the assembly, ensuring no mechanical tension is applied to the connector junctions during machine operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be shortened to fit a specific installation?\u003c\/p\u003e\n\u003cp\u003eA: No. The cable is calibrated for a specific system length; cutting or splicing will create impedance discontinuities and result in measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable compatible with legacy 3300 series systems?\u003c\/p\u003e\n\u003cp\u003eA: No. It is engineered specifically for the 3300 XL platform and is not electrically or mechanically compatible with older 3300 series proximity equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the benefit of the protective connector option?\u003c\/p\u003e\n\u003cp\u003eA: This option includes enhanced housing protection, offering better resistance to contaminants and incidental mechanical stress at the connection point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does ambient temperature affect cable performance?\u003c\/p\u003e\n\u003cp\u003eA: The cable is designed for operation between -51 deg C and +177 deg C. Do not manipulate the cable at the low end of this range to avoid insulation cracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the shield provide electrical return?\u003c\/p\u003e\n\u003cp\u003eA: No. The coaxial shield is intended for electromagnetic isolation. The return path is the outer braid, which must be connected correctly to the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this with non-Bently Nevada Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: No. The system is designed as a matched set; performance cannot be guaranteed when using hardware from different manufacturers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I identify if the extension cable is failing?\u003c\/p\u003e\n\u003cp\u003eA: A failed cable often results in a loss of gap voltage or erratic vibration readings. Verify continuity and inspect the connectors for corrosion or debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of moisture in the connector?\u003c\/p\u003e\n\u003cp\u003eA: Moisture ingress will create signal leakage and erratic data. Ensure connectors are sealed with the provided protective caps when not mated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518766899373,"sku":"330730-080-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330730-080-02-00-extension-cable-tlvtubhf1un.jpg?v=1766977094","url":"https:\/\/www.maxwellplc.com\/products\/330730-080-02-00-bently-nevada-3300-xl-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}