{"product_id":"330730-080-01-00-bently-nevada-3300-xl-11-mm-series-extension-cable","title":"330730-080-01-00 Bently Nevada 3300 XL 11 mm Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330730-080-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between an 11 mm Proximity Probe and a Proximitor Sensor within 3300 XL Machinery Protection System platforms. This coaxial cable maintains the integrity of the high-frequency carrier signal by ensuring specific capacitance and impedance characteristics required for accurate, linear translation of shaft displacement and vibration.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330730\u003c\/strong\u003e: 3300 XL 11 mm Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e080\u003c\/strong\u003e: Cable length option (8.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Connector option (Miniature coaxial ClickLoc connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (No approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330730-080-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot applicable (Passive transmission component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, 75 ohm impedance nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc (Miniature Coaxial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm system relies on the extension cable's precise electrical characteristics to maintain proper eddy-current probe scaling. The total system length, defined by the probe and this extension cable, determines the phase shift and attenuation of the radio frequency carrier signal. Field calibration must ensure that the total length matches the Proximitor's design requirements to facilitate gap voltage validation (-10 VDC targets). Maintaining proper shielding and cross-talk suppression by routing through dedicated conduits ensures that the signal remains uncontaminated by transient electromagnetic noise.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330730-080-01-00 8.0 m Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Connector Protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Technical Installation Leaflet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the coaxial cable through a grounded metallic conduit system to isolate the signal from AC power lines and minimize EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eObserve a minimum bend radius of 25.4 mm (1.0 in) to prevent damaging the internal dielectric or shielding layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFully engage the ClickLoc connectors at both the probe and Proximitor interfaces until a positive lock is confirmed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse the provided connector protector or self-fusing silicone tape to seal the junction against moisture ingress in high-humidity environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs it possible to shorten the 8.0 m cable to a custom length?\u003c\/p\u003e\n\u003cp\u003eNo, the cable length is critical to the system's electrical tuning. Cutting or splicing will alter the capacitance and invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be used with an 8 mm probe system?\u003c\/p\u003e\n\u003cp\u003eNo, the 330730 extension cable is specifically designed for 11 mm systems; using it with 8 mm hardware will result in significant signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the ClickLoc connector hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the connection can be disconnected or reconnected while the system is energized without damaging hardware, though a transient channel fault will occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of moisture on the coaxial interface?\u003c\/p\u003e\n\u003cp\u003eMoisture creates leakage paths that shift the gap voltage reading. Proper sealing with a connector protector is necessary to ensure consistent measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable require specific grounding?\u003c\/p\u003e\n\u003cp\u003eThe cable shield is grounded through the connection to the Proximitor; ensure the system monitor and Proximitor are correctly bonded to a common ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of exceeding the minimum bend radius?\u003c\/p\u003e\n\u003cp\u003eBending the cable too sharply can deform the internal conductor or dielectric, leading to impedance mismatch and signal instability or attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there any active components within this cable?\u003c\/p\u003e\n\u003cp\u003eNo, the extension cable is a passive component containing only the coaxial conductor, shielding, and insulating jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the cable be secured within a junction box?\u003c\/p\u003e\n\u003cp\u003eEnsure the cable is supported to avoid strain on the ClickLoc connectors and kept away from vibration-prone structures that could cause chafing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026844635309,"sku":"330730-080-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_652cb22f-42d8-46a8-a022-a3a0ffffb3ca.jpg?v=1782722531","url":"https:\/\/www.maxwellplc.com\/products\/330730-080-01-00-bently-nevada-3300-xl-11-mm-series-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}