{"product_id":"330730-040-03-00-bently-nevada-3300-xl-series-extension-cable","title":"330730-040-03-00 Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330730-040-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute axial position, ramp differential expansion, and speed signal transmission across 3300 XL Series platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Code Identification Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330730\u003c\/strong\u003e: Base model designator for 3300 XL 11 mm extension cable system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040\u003c\/strong\u003e: 4.0 meters (13.1 feet) total physical cable length option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Stainless steel armored cable path supplied with an integrated coaxial connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Localized hazardous area agency approval certifications not required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Reference Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330730-040-03-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 x 18 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C (-40 to +185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive component linked to Proximitor sensor circuit loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Scaling factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 V\/mm (100 mV\/mil) when combined with 11 mm transducer elements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ohms nominal impedance profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 304 stainless steel (SST) protection sheath\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector layout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 to +105 deg C (-62 to +221 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer System Calibration and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe coaxial architecture transmits dynamic sensor inputs directly to the conditioning stage without modifying factory eddy-current probe scaling metrics. Field engineers execute gap voltage validation (-10 VDC targets) through the extension path during static setup to guarantee proper voltage scaling across the full 11 mm measurement zone. This layout transfers complex rotor dynamics oscillations up to high frequency bands while maintaining structural cross-talk suppression between individual probe loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330730-040-03-00 3300 XL 11 mm Armored Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory-Installed Coaxial Connector Protector Sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation and Routing Guidelines\u003c\/h3\u003e\n\u003ch3\u003eArmored Cable Routing\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the AISI 304 stainless steel armored casing along structural frame brackets, avoiding sharp bends or high-velocity friction points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the 4.0 meters length within protective conduit runs if deployment tracks run past high-temperature machinery casings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClickLoc Connection Engagement\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJoin the miniature ClickLoc coaxial terminals by pushing them together axially until the locking mechanism fully seats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the factory connector protector directly over the joined junction to prevent liquid ingress and ground path shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific 11 mm extension cable support hot-swapping or live decoupling while the loop is powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap operations are unsupported; isolate the primary Proximitor input power prior to uncoupling or servicing any coaxial connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific electrical error arises if the total length deviates from the calibrated 4.0 meters option?\u003c\/p\u003e\n\u003cp\u003eAltering the physical length changes the nominal 50 ohms impedance, which degrades eddy-current probe scaling and causes measurement drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the integrated AISI 304 stainless steel armor protect the internal coaxial signal core?\u003c\/p\u003e\n\u003cp\u003eThe interlocking stainless steel armor provides physical crush protection and shields the interior dielectric layers against mechanical shearing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat parameters define the transport shipping dimensions and total mass for receipt logging?\u003c\/p\u003e\n\u003cp\u003eThe product exhibits an unboxed mass configuration of 0.14 kg inside boxed logistics boundaries measuring 18 x 18 x 1.5 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy must gap voltage validation (-10 VDC targets) be verified through this extension link during commissioning?\u003c\/p\u003e\n\u003cp\u003eVerifying -10 VDC ensures the combined probe and extension path drops the sensor target into the absolute center of its linear calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 3300 XL extension cable be spliced or repaired in the field using standard wire connectors?\u003c\/p\u003e\n\u003cp\u003eNo, terminal splicing is strictly prohibited because standard wire blocks introduce impedance mismatches that destroy the signal scaling factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact function is served by the integrated connector protector element defined by option 03?\u003c\/p\u003e\n\u003cp\u003eThe connector protector physically seals the ClickLoc junction, maintaining structural cross-talk suppression and blocking oil or water contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this extension cable backward compatible with legacy 7200-series 11 mm transducer modules?\u003c\/p\u003e\n\u003cp\u003eNo, upgrading from a 7200-series layout requires replacing all system elements with matching 3300 XL 11 mm components and updating rack software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026846830765,"sku":"330730-040-03-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--1_809cef47-2265-4f28-9147-8bde152d63b7.jpg?v=1782721940","url":"https:\/\/www.maxwellplc.com\/products\/330730-040-03-00-bently-nevada-3300-xl-series-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}