{"product_id":"330709-000-040-50-02-00-bently-nevada-3300-xl-11mm-series-proximity-probes","title":"330709-000-040-50-02-00 Bently Nevada 3300 XL 11mm Series Proximity Probes","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330709-000-040-50-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330709\u003c\/strong\u003e Proximity Probes, operates as a dedicated hardware component for non-contacting displacement and vibration measurement within 3300 XL 11mm Series platforms. The module executes proximity sensing by projecting a high-frequency electromagnetic field onto a target surface, translating proximity deviations into proportional electrical signals for machinery diagnostic systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330709\u003c\/strong\u003e: 3300 XL 11 mm Probe base configuration with M16 x 1.5 metric thread, supplied without mechanical armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-000\u003c\/strong\u003e: Unthreaded Length Option specifying 0 mm of unthreaded case profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-040\u003c\/strong\u003e: Overall Case Length Option establishing a 40 mm mechanical case length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-50\u003c\/strong\u003e: Total Length Option defining a 5.0 meters (16.4 feet) integral connection cable length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Connector and Cable-Type Option utilizing a miniature coaxial ClickLoc connector matched with standard cable construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Agency Approval Option indicating no certification approvals are required for the field build.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330709-000-040-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.6 x 2.3 x 119.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C front tip range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer component powered by external Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM16 x 1.5 metric thread layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet) nominal length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Configuration\u003c\/td\u003e\n\u003ctd\u003eUnarmored flexible outer sheath construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330709-000-040-50-02-00 relies on precise eddy-current probe scaling matrices within the matched Proximitor sensor assembly to maintain a constant electrical calibration factor. Correct positioning requires verification of gap voltage validation parameters until the probe tip settles into the optimum -10 VDC target midpoint zone. This calibration profile optimizes cross-talk suppression during close-proximity dual-axis configurations, ensuring high-frequency displacement inputs are captured accurately to track complex rotor dynamics behaviors.\u003c\/p\u003e\n\u003ch3\u003eKit Packaging List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330709-000-040-50-02-00 Proximity Probe Assembly\u003c\/li\u003e\n\u003cli\u003e2 x Hexagonal Mounting Nuts for M16 x 1.5 Threads\u003c\/li\u003e\n\u003cli\u003e1 x Coaxial Terminal Interface Protective Cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetric Thread Torque Limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure the M16 x 1.5 threaded case into the mounting flange using a torque wrench, checking that the clamping force remains within manufacturer limits to eliminate housing stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc Coupling Cleanliness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClean all electrical connection surfaces before engaging the miniature coaxial ClickLoc connector, keeping the contacts free of lubricants and industrial particulate matter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the 5.0 meters unarmored standard cable while maintaining a minimum bend radius of 25.4 mm (1.0 inch) to protect the internal coaxial shielding from stress fractures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Conduit Isolation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIsolate the unarmored cable run inside a dedicated protective conduit network to shield the coaxial assembly from mechanical impact and high-voltage line interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan the ClickLoc connector joint on this 5.0-meters probe lead be hot-swapped while the Proximitor loop is fully powered?\u003c\/p\u003e\n\u003cp\u003eYes, but doing so will instantly open the input channel loop, triggering a transient fault state and immediate invalidation of the associated gap voltage logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the total cable system distance does not match the standard 5.0-meters calibration profiles?\u003c\/p\u003e\n\u003cp\u003eExceeding or dropping below designated length matching specifications alters loop capacitance, which completely disrupts the eddy-current probe scaling and results in measurement drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does an operator verify whether the probe tip has reached the proper physical installation gap depth?\u003c\/p\u003e\n\u003cp\u003eConnect a digital multimeter to the Proximitor monitor test ports and adjust the depth until the DC voltage settles at the standard -10 VDC target value.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of surface preparation is required on the target shaft area to prevent measurement phase error logs?\u003c\/p\u003e\n\u003cp\u003eThe target track must be machined to mirror finishes, ensuring low electrical runout values to prevent cross-talk suppression artifacts from altering rotor dynamics calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this specific option version compatible with direct installation inside high-pressure fluid environments?\u003c\/p\u003e\n\u003cp\u003eNo, standard probes with zero unthreaded length option require a protective mechanical sleeve or thermowell assembly if placed into areas with high fluid flow or high pressures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy does this assembly specify an unarmored configuration instead of an armored flexible lead?\u003c\/p\u003e\n\u003cp\u003eThe unarmored version provides a lower physical profile and higher flexibility, making it ideal for tight spaces where rigid conduits already provide mechanical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline indicator points out that the internal coaxial core wire has suffered an electrical break?\u003c\/p\u003e\n\u003cp\u003eThe primary monitoring chassis will turn off the front channel OK LED indicator and output an out-of-bounds low limit signal below -1 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this M16 x 1.5 thread probe module be mounted in a standard imperial thread bracket structure?\u003c\/p\u003e\n\u003cp\u003eNo, attempting to cross-thread the metric body into an imperial clearance hole will destroy the precision case threading and ruin the sensor assembly geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025260564653,"sku":"330709-000-040-50-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_13_ce9c7b7d-8d7a-497e-b5ad-0e86634ec719.jpg?v=1783781943","url":"https:\/\/www.maxwellplc.com\/products\/330709-000-040-50-02-00-bently-nevada-3300-xl-11mm-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}