{"product_id":"330705-02-18-10-02-00-bently-nevada-reverse-mount-probe-3300-xl-nsv","title":"330705-02-18-10-02-00 Bently Nevada Reverse Mount Probe 3300 XL NSv","description":"\u003cp\u003eConfigured for displacement sensing in constrained machinery envelopes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330705-02-18-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330705-02-18-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReverse Mount Probe) provides direct physical execution of eddy-current signal sensing within rotating machinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330705: 3300 XL NSv Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Unthreaded length (20 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e18: Overall case length (180 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length (1.0 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector type (Miniature coaxial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval (Not required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330705-02-18-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 x 15.0 x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003ePrecise eddy-current probe scaling is required to maintain measurement accuracy, particularly in small-bore applications where the NSv system is utilized. System output must be verified through gap voltage validation, with a nominal -10 VDC target at the calibrated mid-range position. Engineers must implement effective cross-talk suppression by ensuring physical spacing between adjacent probes exceeds minimum specifications, preventing interference in the high-frequency carrier signal. Correct interpretation of rotor dynamics relies on the stability of this probe assembly under thermal and mechanical loading.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 330705-02-18-10-02-00 Reverse Mount Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set mounting hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 technical reference guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: The reverse mount configuration requires installation from the interior of the machine case or housing. Ensure the jam nut is tightened to specified torque to prevent rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain electrical isolation between the probe housing and the machine case unless the specific monitoring configuration mandates a bonded ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route the coaxial cable through a protected conduit path to avoid mechanical fatigue and prevent induced noise from local electromagnetic fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Calibration: Set the static air gap using a precision tool. Verify that the proximitor output matches the target voltage before initiating machine rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330705 probe compatible with standard 3300 XL proximitors?\u003c\/p\u003e\n\u003cp\u003eNo, the 330705 NSv probe is designed specifically for use with 3300 XL NSv proximitors to accommodate the smaller tip geometry and frequency response requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary advantage of the reverse mount design?\u003c\/p\u003e\n\u003cp\u003eThe reverse mount configuration allows the probe to be installed in locations where access is restricted from the exterior, facilitating mounting within housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be used at temperatures above 177 deg C?\u003c\/p\u003e\n\u003cp\u003eNo, exceeding the maximum operating temperature will result in degradation of the internal coil potting and potential signal failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require a specific target material?\u003c\/p\u003e\n\u003cp\u003eThe factory calibration assumes AISI 4140 steel. Variations in target alloy will change the sensitivity and require system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk avoided in compact installations?\u003c\/p\u003e\n\u003cp\u003eStrict adherence to probe-to-probe separation distances is required to prevent beat frequencies caused by the high-frequency oscillator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the cable is cut or damaged?\u003c\/p\u003e\n\u003cp\u003eThe probe and cable are an integrated factory-sealed assembly. Damage to any part of the unit necessitates the replacement of the entire probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector waterproof?\u003c\/p\u003e\n\u003cp\u003eThe miniature coaxial connector is designed for use in protected, dry environments. It is not intended for direct immersion or exposed exterior installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should gap voltage be measured?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance digital multimeter connected to the proximitor output terminals to confirm the voltage is within the expected range for the set gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819557549,"sku":"330705-02-18-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330705-02-18-10-02-00-reverse-mount-probe-2td30amvvb3.jpg?v=1766979489","url":"https:\/\/www.maxwellplc.com\/products\/330705-02-18-10-02-00-bently-nevada-reverse-mount-probe-3300-xl-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}