{"product_id":"330704-000-060-90-02-cn-bently-nevada-proximity-probe-3300-xl-series","title":"330704-000-060-90-02-CN Bently Nevada Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for high-precision displacement and vibration measurement in industrial rotating equipment, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330704-000-060-90-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330704\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical execution of eddy-current based signal transduction within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number 330704-000-060-90-02-CN identifies the following transducer hardware configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330704: 11 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e060: Overall Case Length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e90: Total Length (9.0 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Country-Specific Agency Approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330704-000-060-90-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA \/ International\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 25 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowered via 3300 XL Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 11 mm probe system relies on specialized eddy-current probe scaling to convert shaft motion into a proportional voltage output. System accuracy depends on strict gap voltage validation; the -10 VDC target is required to maintain linearity during vibration monitoring. Cross-talk suppression must be observed during the installation of multi-probe arrays. Proper spatial separation is mandatory to prevent electromagnetic field interference and signal distortion, which are intrinsic risks when operating high-density transducer configurations on large-diameter shafts.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330704 11 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector thread protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation and compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e: Secure the probe body into the mounting bracket using the locknut. Ensure the probe tip is installed perpendicular to the target shaft surface to maintain geometric measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Adjustment\u003c\/strong\u003e: Set the nominal air gap at standstill using a high-impedance digital voltmeter at the Proximitor sensor output, ensuring alignment with the required dynamic clearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Protocols\u003c\/strong\u003e: Terminate the coaxial cable shield at the monitoring system common ground to prevent ground loops and electromagnetic noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Separation\u003c\/strong\u003e: Route signal cables through dedicated, non-metallic conduit to ensure isolation from high-voltage AC lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTransit and Logistics\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll components utilize anti-static industrial packaging to provide ESD protection and mechanical shock resistance during international shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat material targets are supported?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transducer is factory-calibrated for AISI 4140 steel; other metallic targets require specific calibration curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the probe sensitivity?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe nominal sensitivity is 3.94 V\/mm (100 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should calibration be verified?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCalibration verification is required during scheduled machinery turnarounds or if signal drift is identified in the monitoring software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the probe operate in hazardous environments?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, provided the system is installed in compliance with approved regional hazardous area standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat extension cables are compatible?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnly 3300 XL series coaxial extension cables are designed to match the system impedance requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable gap voltage?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstability is typically the result of compromised coaxial shielding, loose connector contacts, or high-frequency electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is probe health tested?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProbe health is confirmed by measuring coaxial continuity and verifying that the DC output voltage remains stable within the linear window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eService life is determined by thermal exposure and mechanical stress levels at the probe mounting interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518864023725,"sku":"330704-000-060-90-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330704-000-060-90-02-cn-3300-xl-11-mm-proximity-probes-obkqhjpt3se.jpg?v=1766980458","url":"https:\/\/www.maxwellplc.com\/products\/330704-000-060-90-02-cn-bently-nevada-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}