{"product_id":"330190-080-01-00-bently-nevada-3300-xl-series-extension-cable","title":"330190-080-01-00 Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330190-080-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330190\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal path extension between proximity probes and Proximitor sensors within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330190 (Extended Temperature Range Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Length: 8.0 meters (26.2 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Option: Armored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330190-080-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.96 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.5 cm x 30 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +260 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Signal transmission)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Behavior\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system uses high-frequency eddy-current probe scaling to convert target proximity into a proportional voltage signal. This extension cable is designed for environments requiring extended temperature range (ETR) performance. Signal integrity relies on maintaining the specified system capacitance; therefore, the cable impedance is precisely controlled to 50 Ohm. Gap voltage validation at the Proximitor end, typically targeting -10 VDC at the nominal gap, must account for the signal path attenuation inherent in the 8.0-meter length. Cross-talk suppression is maintained by ensuring cable shields are continuous and correctly referenced to the system signal common.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330190-080-01-00 ETR Extension Cable unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory-terminated coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated stainless steel armor for mechanical protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Calibration documentation and mounting clips are excluded from the standard delivery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Avoid running signal cables in parallel with high-voltage AC lines to prevent electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is grounded at the Proximitor end only; multi-point grounding can create ground loops that induce signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25.4 mm (1.0 in) to prevent damage to the internal dielectric and shielding structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Torque: Use a torque-limiting tool (0.565 N m) for all ClickLoc connections to ensure stable electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: The ETR construction is designed for ambient temperatures up to 260 deg C; verify installation surroundings do not exceed this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogistics: Global transit via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging: All items are secured in anti-static industrial packaging to prevent electrostatic discharge and impact damage during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be used with non-ETR probes?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable is electrically compatible with standard 3300 XL probes, though system temperature limits will be defined by the lowest-rated component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the cable capacitance important?\u003c\/p\u003e\n\u003cp\u003eA: The Proximitor sensor is calibrated to compensate for a specific system capacitance; changing cable lengths or types will cause measurement inaccuracies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the armor affect electrical performance?\u003c\/p\u003e\n\u003cp\u003eA: No, the armor is purely mechanical and does not influence the electrical transmission characteristics of the coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is this cable different from standard 330130 cables?\u003c\/p\u003e\n\u003cp\u003eA: The 330190 series utilizes materials rated for extended temperature ranges (up to 260 deg C) compared to standard cable construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is field repair of the connectors permitted?\u003c\/p\u003e\n\u003cp\u003eA: Field repair is not recommended as it compromises the factory-calibrated impedance and environmental sealing of the connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum voltage for the signal path?\u003c\/p\u003e\n\u003cp\u003eA: The signal path operates at low voltage, with the bias supplied by the Proximitor sensor; do not apply external voltage to the signal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How can I verify cable continuity?\u003c\/p\u003e\n\u003cp\u003eA: Use a high-impedance multimeter to check for shield continuity and conductor resistance, ensuring no shorts exist between the inner conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the connectors compatible with ClickLoc systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the connectors are designed for seamless integration with all Bently Nevada ClickLoc-equipped proximity systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026824253613,"sku":"330190-080-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_7584db68-48d3-4031-901b-9e0d34c9d389.jpg?v=1781084868","url":"https:\/\/www.maxwellplc.com\/products\/330190-080-01-00-bently-nevada-3300-xl-series-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}