{"product_id":"330180-x2-00-mod-181634-02-bently-nevada-proximitor-sensor-3300-xl-series","title":"330180-X2-00 MOD:181634-02 Bently Nevada Proximitor Sensor 3300 XL series","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-X2-00 MOD:181634-02\u003c\/strong\u003e serves as the primary \u003cstrong\u003e330180-X2-00 MOD:181634-02\u003c\/strong\u003e Proximitor Sensor utilized to execute non-contact shaft displacement and vibration measurements across machinery protection and condition monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Architecture And Model Identifiers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model: 330180\u003c\/li\u003e\n\u003cli\u003eLength Options: -X2 (supports 1.0 meter or 5.0 meters system lengths)\u003c\/li\u003e\n\u003cli\u003eAgency Approval: -00 (Not required variant)\u003c\/li\u003e\n\u003cli\u003eModification Code: MOD:181634-02\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specification Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X2-00 MOD:181634-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 3.5 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered via monitor (No dedicated local supply rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eA308 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics And Signal Linearity Execution\u003c\/h3\u003e\n\u003cp\u003eThe unit conditions high-frequency radio frequency signals delivered to probe tips, relying on eddy-current probe scaling to convert physical gap changes into proportional electrical outputs. Technicians must perform precise gap voltage validation targeting -10 VDC nominal baselines during initial calibration to ensure operation within the linear range. The internal circuitry suppresses signal distortion and preserves high-fidelity phase relationships, preventing cross-talk interference across parallel channels monitoring rotating shafts.\u003c\/p\u003e\n\u003ch3\u003eSupply Manifest And Scope Of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 x 330180-X2-00 MOD:181634-02 Proximitor Sensor units\u003c\/li\u003e\n\u003cli\u003eNote: Interconnect cables, probe tips, and mounting brackets are excluded unless specified in separate purchasing documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Grounding: Mount the sensor unit on isolated mounting plates to eliminate ground loops and prevent electrical noise ingress from the machine skid.\u003c\/li\u003e\n\u003cli\u003eCable Routing: Keep coaxial signal extensions separated from high-voltage motor cables and variable frequency drives to avoid electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eShielding Rules: Terminate the coaxial shield strictly at the monitor termination side to maintain proper signal grounding integrity.\u003c\/li\u003e\n\u003cli\u003eThread Engagement: Adhere to standard mechanical installation tolerances and torque specifications when securing physical probe assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiries And Field Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary operational function of this hardware component?\u003c\/p\u003e\n\u003cp\u003eA: It processes high-frequency signals to measure static and dynamic radial vibration and axial position in machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What baseline voltage is targeted during sensor gap adjustment?\u003c\/p\u003e\n\u003cp\u003eA: Initial alignment requires verifying a nominal -10 VDC output to ensure the transducer operates within its linear measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What material composes the outer enclosure of the sensor?\u003c\/p\u003e\n\u003cp\u003eA: The housing is manufactured using robust A308 aluminum material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the permissible operating temperature range?\u003c\/p\u003e\n\u003cp\u003eA: The unit functions reliably within an ambient temperature range of -52 deg C to +100 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are extension cables included in the standard shipping package?\u003c\/p\u003e\n\u003cp\u003eA: No, standard delivery contains solely the sensor unit unless ordered alongside matched extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is power supplied to the Proximitor circuit?\u003c\/p\u003e\n\u003cp\u003eA: Power is delivered directly through the signal loop powered by the corresponding monitor channel in the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What output impedance does the circuit feature?\u003c\/p\u003e\n\u003cp\u003eA: The internal output resistance is configured at 50 Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should cable shields be managed during installation?\u003c\/p\u003e\n\u003cp\u003eA: Shields must remain continuous and be grounded exclusively at the monitor end to suppress electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025805398189,"sku":"330180-X2-00 MOD:181634-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-x2-00_13.jpg?v=1783664009","url":"https:\/\/www.maxwellplc.com\/products\/330180-x2-00-mod-181634-02-bently-nevada-proximitor-sensor-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}