{"product_id":"330180-x1-05-bently-nevada-3300-system-mod-145004-57-3300-xl-proximitor-sensor","title":"330180-X1-05 Bently Nevada 3300 System MOD:145004-57 3300 XL Proximitor Sensor","description":"\u003cp\u003eConfigured for high-precision displacement sensing in industrial monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-X1-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330180\u003c\/strong\u003e) Proximitor Sensor provides direct physical signal transduction of rotor position and vibration within mechanical clearances.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.5 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult 3300 XL technical manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLoop-powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA308 Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated brass\/beryllium copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output. Accurate rotor dynamics analysis depends on gap voltage validation to target the -10 VDC reference at the Proximitor output, which establishes the baseline for displacement measurements. The internal circuitry provides robust cross-talk suppression, ensuring signal integrity is maintained even when multiple sensors are mounted in high-density proximity arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330180-X1-05 Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation and technical documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the Proximitor housing to a grounded, vibration-free surface using the integrated mounting holes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the enclosure is protected from direct exposure to process fluids or extreme environmental contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the coaxial probe cable to the Proximitor input, ensuring the connector is seated to prevent signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate the signal output to the monitor rack backplane, ensuring proper shield continuity to ground to mitigate common-mode interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the role of the Proximitor Sensor?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor acts as the signal conditioner for eddy-current probes, providing the high-frequency drive signal and converting the probe output into a usable voltage signal for monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use a different system length cable?\u003c\/p\u003e\n\u003cp\u003eNo, the system is factory-calibrated as a matched set. Using a probe or extension cable of a different length than specified will invalidate the measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the gold-plated connectors?\u003c\/p\u003e\n\u003cp\u003eGold plating provides corrosion resistance and ensures a consistent, low-resistance electrical connection for sensitive vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this sensor compatible with all 3300 XL probes?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor must be matched to the specific resonant frequency of the probe\/cable system; always verify compatibility with the specific 3300 XL probe model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the sensor housing grounded?\u003c\/p\u003e\n\u003cp\u003eThe aluminum housing should be mounted to a conductive, grounded surface to ensure proper electromagnetic shielding of the internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the device be hot-swapped?\u003c\/p\u003e\n\u003cp\u003eThe device can be replaced in the field, but the monitoring system should be set to a maintenance mode to prevent false alarms during the transition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the agency approval implications?\u003c\/p\u003e\n\u003cp\u003eThe 05 suffix indicates the device has passed rigorous safety standards for use in explosive atmospheres as defined by CSA, ATEX, and IECEx.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the typical gap voltage reference?\u003c\/p\u003e\n\u003cp\u003eStandard calibration targets a -10 VDC output when the probe is set at its nominal mid-range gap distance from the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026797252781,"sku":"330180-X1-05 MOD:145004-57","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/330180-X1-05_2.jpg?v=1782898608","url":"https:\/\/www.maxwellplc.com\/products\/330180-x1-05-bently-nevada-3300-system-mod-145004-57-3300-xl-proximitor-sensor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}