{"product_id":"330173-00-06-10-02-cn-bently-nevada-3300-series-proximity-probes","title":"330173-00-06-10-02-CN Bently Nevada 3300 Series Proximity Probes","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for precision shaft displacement monitoring in mechanical protection platforms, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"95\"\u003eBently Nevada 330173-00-06-10-02-CN\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"132\"\u003e330173\u003c\/b\u003e Proximity Probes) provides direct physical execution of eddy-current distance sensing.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Suffix Decomposition\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e330173: 3300 5 mm probe, M8 x 1 thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e00: 0.0 mm minimum unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e06: 60 mm minimum unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e10: 1.0 m (3.3 feet) total length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e02: Miniature coaxial ClickLoc connector, standard cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003eCN: Agency approval variant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003e330173-00-06-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e113 x 1.8 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003ePassive transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eThreading\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003eM8 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTSI and Mechanical Dynamics\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe 3300 series utilizes eddy-current probe scaling to convert target proximity into electrical signals. Linearity is maintained through gap voltage validation, with -10 VDC targets required to center the probe within its operational range. To ensure accurate rotor dynamics data, the system employs cross-talk suppression by adhering to specified spacing requirements in multi-probe arrays. Proper installation requires verification of target surface diameter to eliminate field edge effect errors, which otherwise manifest as non-linear measurement behavior.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eOrdering Info\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 330173-00-06-10-02-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 M8 x 1 locking nut assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eMechanical Mounting: Thread the probe into the M8 x 1 mounting aperture, ensuring sufficient engagement to prevent loosening from machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eConnector Engagement: Tighten the ClickLoc connector until the locking mechanism is fully seated to maintain signal impedance integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003eGrounding: Secure the coaxial cable shield at the Proximitor sensor ground terminal to eliminate ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003eCalibration: Use a digital voltmeter to verify a -10 VDC gap voltage during static machine conditions to ensure the probe tip is centered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eCan this probe be used without a Proximitor sensor?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eNo. This probe is a passive component and requires a matched 3300 series Proximitor to condition the eddy-current signal for system output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eIs the cable length field-modifiable?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eNo. The system is factory-calibrated for a 1.0 m length; modifying the cable alters circuit impedance and invalidates the measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eWhat is the consequence of exceeding the linear range?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eExceeding the linear range results in signal clipping and non-linear response, leading to invalid vibration amplitude and position data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eAre the ClickLoc connectors water-tight?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eThe connectors provide a secure mechanical interface but require additional environmental protection if installed in locations subject to direct fluid spray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eCan the probe withstand high-temperature environments?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eYes. The probe is designed for operation up to 177 deg C, provided the coaxial cable dielectric and connector are similarly rated for the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eDoes the probe require specialized grounding?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eThe probe body is grounded via the machine casing; ensure the mounting threads are free of insulating paint or coatings to maintain electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eWhat causes signal drift during operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eSignal drift is typically caused by variations in gap voltage or thermal expansion of the probe mounting assembly, requiring periodic system verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eAre the grommets in the installation kit reusable?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eGrommets are designed for a single compression cycle. If the probe is reinstalled, inspect the grommets for deformation and replace if necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026780377261,"sku":"330173-00-06-10-02-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_0acd5ef0-6036-441e-8204-91dc042ba5e0.jpg?v=1783410409","url":"https:\/\/www.maxwellplc.com\/products\/330173-00-06-10-02-cn-bently-nevada-3300-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}