{"product_id":"330130-085-13-cn-bently-nevada-3300-xl-standard-extension-cable","title":"330130-085-13-CN Bently Nevada 3300 XL Standard Extension Cable","description":"\u003cp\u003eConfigured for specific electrical length matching in machinery protection networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-085-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Extension Cable) provides direct physical\/electrical execution. The coaxial assembly links an 8 mm proximity probe to a 3300 XL Proximitor Sensor, maintaining loop impedance boundaries required to transmit high-frequency eddy-current displacement signals back to the central processing rack.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: 3300 XL Standard Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-085\u003c\/strong\u003e: Cable length option (8.5 meters \/ 27.9 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-13\u003c\/strong\u003e: Connector and cable option (Stainless steel armor with connector protector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e: Agency approval option (China RoHS and local hazardous area certification)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensional and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-085-13-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 mm x 250 mm x 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive element (Zero internal power dissipation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohms nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e62.3 pF\/m nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 inch) for armored variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Loop Tuning\u003c\/h3\u003e\n\u003cp\u003eThe hardware directly affects eddy-current probe scaling by introducing a fixed capacitive and inductive load to the RF oscillator circuit. To achieve correct gap voltage validation matching the -10 VDC baseline at physical center, the overall physical system length (probe plus extension cable) must accurately total 9.0 meters when paired with a 0.5-meter probe, or 10.0 meters if specified by alternative system tuning. Proper installation maintains strict cross-talk suppression by shielding the core conductor within a braided metallic wrap enclosed in stainless steel armor, preventing overlapping electromagnetic fields from adjacent rotor dynamics monitoring channels from introducing signal noise.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330130-085-13-CN Armored Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Integrated Coaxial Connector Protector (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical Inspection and Continuity Data Record\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Routing and Connection Specifications\u003c\/h3\u003e\n\u003cp\u003ePhysical installation requires strict adherence to bend limits and grounding protocols to protect signal transmission.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the armored cable length from the proximity probe junction box to the Proximitor enclosure using dedicated physical conduits or tray networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25.4 mm throughout the cable run to avoid fracturing the internal coaxial shielding layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJoin the miniature coaxial ClickLoc connectors by pushing and twisting the terminal ends together until fully seated. Slide the pre-installed connector protector over the junction to eliminate moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulate the extension cable armor from structural machine metals. The system shield must remain isolated from ground until its termination point inside the Proximitor Sensor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eLogistics Frame and Packaging\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, utilizing express dispatch services including DHL, FEDEX, and UPS. All shipments utilize sealed anti-static industrial packaging and custom internal supportive padding to eliminate physical stress and preserve mechanical characteristics during international transport.\u003c\/p\u003e\n\u003ch3\u003eComponent Performance FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can a 330130-085 extension cable be cut or spliced to fit localized enclosure distances?\u003c\/p\u003e\n\u003cp\u003eA: No. The extension cable length is precisely matched to provide the specific capacitance required for factory eddy-current probe scaling. Cutting or splicing the cable alters the electrical length, making gap voltage validation at -10 VDC impossible and causing severe calibration drift across the linear range.\u003c\/p\u003e\n\u003cp\u003eQ: Is this extension cable compatible with older non-XL 3300 series 8 mm proximity probes?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 3300 XL extension cable is physically and electrically backwards compatible with standard 3300 series 8 mm probes and Proximitor Sensors. However, mixing components may limit the system to the temperature and linear specifications of the older hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Does hot-swapping the extension cable damage the linked 3500 rack channels?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting the cable while the system is live is a safe field operation because the cable contains no active electronic components. The monitoring module will instantly report a transducer fault (NOT OK status) due to the open circuit loop, but no hardware degradation occurs.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518832533677,"sku":"330130-085-13-CN","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-085-13-cn-3300-xl-standard-extension-cable-aqmwgpo3gmp.jpg?v=1766979896","url":"https:\/\/www.maxwellplc.com\/products\/330130-085-13-cn-bently-nevada-3300-xl-standard-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}