{"product_id":"330130-075-02-05-bently-nevada-3300-xl-extension-cables","title":"330130-075-02-05 Bently Nevada 3300 XL Extension Cables","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-075-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cables) serves as a precision-engineered signal transmission link within the 3300 XL 8 mm Proximity Transducer System. By bridging the physical gap between the machine-mounted proximity probe and the Proximitor sensor located in the instrumentation cabinet, this cable assembly maintains the controlled impedance required for accurate eddy-current signal propagation. It is constructed to preserve the integrity of high-frequency shaft vibration and position data without attenuation or phase distortion, ensuring reliable performance in turbomachinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330130-075-02-05 assembly is defined by the following configuration parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e075: Cable length (7.5 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector configuration (Miniature coaxial, standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval and certification classification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-075-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 30 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, Shielded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClick-loc Miniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop signal path)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI \u0026amp; Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eAccurate rotor dynamics analysis requires precise signal calibration across the entire transducer loop. The 330130 extension cable is factory-tuned to maintain constant system impedance, which is critical for validating gap voltage at the -10 VDC nominal center-point. Any impedance mismatch introduced by non-standard cabling would induce non-linearity and frequency response shifts, undermining the machine protection system's ability to interpret vibration vectors. These assemblies utilize shielded coaxial paths specifically designed to suppress cross-talk and prevent electromagnetic interference from contaminating raw signal waveforms.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130 3300 XL Extension Cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector thread caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Cable length is fixed based on system calibration requirements; ensure the total loop length (Probe + Extension Cable) matches the configuration of the Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Integrity: Inspect mating surfaces for contamination before coupling; use a non-residue cleaner if required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMating Procedure: Engage the Click-loc connectors fully to ensure a secure, low-impedance connection; avoid using pliers to tighten, as this can crush the internal dielectric.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Routing: Install cabling through grounded, rigid metallic conduit to provide shielding and prevent mechanical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 5 times the cable diameter to prevent internal impedance changes caused by dielectric deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Strategy: Ensure a single-point ground connection at the instrumentation cabinet to eliminate ground loops that can induce 50\/60 Hz signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be shortened if the 7.5-meter length is too long?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The cable is a precision-calibrated component of the transducer system. Cutting it will change the system impedance and invalidate accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 330130 cable compatible with older 3300-series hardware?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. This cable is specifically designed for 3300 XL transducer systems; using it with legacy hardware will result in signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How can I tell if the cable is causing signal noise?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: If you observe high noise floors or intermittent DC bias shifts, inspect the connector for moisture or the cable jacket for physical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the connectors submersible?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. They are intended for dry, protected environments. Use a junction box if installation occurs in areas prone to moisture or oil spray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the benefit of the Click-loc connector?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The Click-loc design ensures a vibration-resistant, low-resistance interface that maintains signal stability in high-vibration turbomachinery environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should I apply electrical tape to the connection point?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Only if required by site-specific standards; in most cases, a clean, dry, properly mated connection is superior to taped joints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this cable on a non-conductive target?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The cable is designed for 3300 XL systems which utilize eddy-current sensing; the target must be conductive for the system to generate a signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the 05 suffix imply hazardous area compliance?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the 05 suffix indicates specific agency approvals for hazardous environments; confirm the rating against local safety site requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826078381,"sku":"330130-075-02-05","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-075-02-05-extension-cable-fwen5m0hit0.jpg?v=1766979689","url":"https:\/\/www.maxwellplc.com\/products\/330130-075-02-05-bently-nevada-3300-xl-extension-cables","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}