{"product_id":"330130-045-02-00-bently-nevada-3300-xl-extension-cable","title":"330130-045-02-00 Bently Nevada 3300 XL Extension Cable","description":"\u003cp\u003eConfigured for high-frequency signal propagation in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-045-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Extension Cable) serves as a dedicated hardware interface connecting proximity probes to signal conditioning modules. This component maintains the electrical impedance required to ensure signal integrity across the transducer chain within machine protection networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330130-045-02-00 designation represents the following configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e045: Cable length of 4.5 meters (14.8 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Standard cable with integrated connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval not required for this configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-045-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 cm x 28 cm x 3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Passive component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Signal Dynamics and Rotor Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on a consistent 75 Ohm coaxial path to translate eddy-current fluctuations into precise displacement data. Accurate rotor dynamics analysis, including orbital plots and shaft centerline tracking, requires precise eddy-current probe scaling to remain within the linear operational range. Technicians must target gap voltage validation of -10 VDC at the monitor input to compensate for signal path characteristics. Effective cross-talk suppression must be implemented by maintaining physical isolation between extension cables and high-voltage AC lines; failure to isolate these signals introduces electromagnetic noise, which directly degrades vibration magnitude readings and system measurement fidelity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130-045-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-installed connector protectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation and installation guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Cable Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Routing: Install cables within dedicated, grounded metallic conduits to provide shielding against external electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to a minimum bend radius of 2.5 cm to ensure the structural integrity of the coaxial dielectric and internal signal conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Security: Ensure connectors are fastened finger-tight; the use of mechanical tools for tightening risks damaging internal pin alignment and locking mechanisms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMoisture Protection: Utilize the integrated connector protector in environments exposed to oil mist or high humidity to prevent oxidation of the electrical contact surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponents are sealed in anti-static industrial packaging to mitigate ESD events and mechanical deformation during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material targets are supported? The transducer system is factory-calibrated for AISI 4140 steel. Variations in target material magnetic permeability require a site-specific scale factor adjustment to maintain linearity and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the probe sensitivity? This extension cable maintains the standard 7.87 V\/mm (200 mV\/mil) sensitivity of the 3300 XL transducer system throughout the signal transmission path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow often should calibration be verified? Verification of loop resistance and signal integrity should be conducted during major machine outages or if the monitoring platform reports persistent gap voltage drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe operate in hazardous environments? This model does not carry hazardous area ratings. Installations requiring intrinsic safety must utilize certified hardware and strictly follow documented control drawings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat extension cables are compatible? Only Bently Nevada 3300 XL series cables are compatible. Mixing non-standard cable lengths or impedance types results in signal attenuation and erroneous vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes unstable gap voltage? Instability is primarily attributed to loose connections, degraded coaxial shielding, or ground loops created by improper conduit grounding techniques.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is probe health tested? Health is validated by measuring the DC loop resistance and verifying the dynamic signal output response at the monitor rack input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the expected service life? Service life is subject to the thermal and mechanical duty cycle of the installation site. Under steady-state conditions, the cable is intended for continuous, long-term operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026853875885,"sku":"330130-045-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10.jpg?v=1781072542","url":"https:\/\/www.maxwellplc.com\/products\/330130-045-02-00-bently-nevada-3300-xl-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}