{"product_id":"330130-040-00-05-bently-nevada-3300-xl-series-proximity-transducer-cable","title":"330130-040-00-05 Bently Nevada 3300 XL Series Proximity Transducer Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-040-00-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency RF signal transmission within 3300 XL Proximity Transducer platforms. Configured for non-contacting displacement and dynamic vibration loop matching in machine protection architectures, the hardware links the proximity probe to the remote Proximitor sensor module without introducing attenuation or impedance anomalies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Options\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Model (330130):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Standard Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length Option (040):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.0 meters (11.5 feet) physical cable span.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protector and Cable Option (00):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard unarmored coaxial cable configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option (05):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA, ATEX, and IECEx hazardous area multi-approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Metrics\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-040-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 x 22.4 x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C mechanical limit rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive RF transmission line component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Cable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 meters (11.5 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ohm nominal loop matching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) typical baseline\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterconnect Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial connection interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Area Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified for hazardous zone placement via CSA, ATEX, IECEx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThis 4.0-meter hardware segment is engineered to maintain exact factory eddy-current probe scaling when matched with a 1.0-meter 3300 XL proximity probe. The resulting 5.0-meter calibrated electrical loop matches the tuning profile of the Proximitor oscillator, allowing accurate tracking of dynamic rotor dynamics parameters. Preserving fixed loop metrics ensures that high-frequency vibration signals remain isolated from phase distortions and enforces cross-talk suppression between orthogonal X-Y radial monitoring channels.\u003c\/p\u003e\n\u003ch3\u003eCoaxial Loop Interface FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: What specific electrical tracking errors arise if this 4.0-meter cable is combined with a 0.5-meter legacy probe?\u003c\/p\u003e\n\u003cp\u003eA: Combining a 4.0-meter extension line with a 0.5-meter probe yields a 4.5-meter total length, which deviates from the required 5.0-meter tuning block. This reduction shifts the loop capacitance away from the factory baseline, distorting the standard 7.87 V\/mm scale factor and degrading accuracy during gap voltage validation.\u003c\/p\u003e\n\u003cp\u003eQ: Is this standard coaxial model optimized to prevent fluid migration along the internal braid?\u003c\/p\u003e\n\u003cp\u003eA: No. This model features option code 00 (Standard Cable). For environments involving pressurized oil or gas migration through the cable interior, a dedicated FluidLoc configuration (Option 10) must be utilized to seal the inner voids.\u003c\/p\u003e\n\u003cp\u003eQ: Can the miniature coaxial connectors be cleaned with standard industrial hydrocarbon solvents?\u003c\/p\u003e\n\u003cp\u003eA: Coaxial interface pins must be cleaned using only residue-free electronic contact cleaners. Hydrocarbon solvent deposits degrade the dielectric performance of the internal insulator, skewing gap measurements and triggering false monitor status indications.\u003c\/p\u003e\n\u003ch3\u003eField Layout and Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Isolation Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the unarmored 4.0-meter coaxial line through dedicated, earthed metallic conduits, avoiding parallel runs next to high-voltage AC motor power paths to block electromagnetic noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Radius Limitations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a continuous physical bend radius of not less than 25.4 mm (1.0 inch) along the cable track to prevent core deformation or structural changes to the internal shielding layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Sleeve Latching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the coaxial connection pins are completely dry before mating. Hand-tighten the miniature coaxial interfaces securely until the mechanical locking mechanism is fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Discipline:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep the extension cable outer shield floating relative to the local machine housing. Ensure the entire circuit shield paths ground exclusively at the machine protection monitor rack ground terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePacking Procurement Items\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponents Contained in Shipped Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne Bently Nevada 330130-040-00-05 4.0-meter standard unarmored extension cable and terminal interface covers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Accessory Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMatching 8 mm non-contacting proximity probes, panel-mount Proximitor driver blocks, and silicone terminal boots are separate lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Packaging Profiles\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransit Turnaround Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDelivery time: 2-7 days when payment finish, routed via prioritized international express courier networks using DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Static Industrial Packaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispatched within heat-sealed anti-static industrial packaging and shipped in rigid outer cartons to prevent crushing or shield layer distortion during international transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026885038253,"sku":"330130-040-00-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian_2_2a0f7ee1-e39f-4580-9bea-c9e41a86911d.jpg?v=1780048390","url":"https:\/\/www.maxwellplc.com\/products\/330130-040-00-05-bently-nevada-3300-xl-series-proximity-transducer-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}