{"product_id":"330130-035-00-00-bently-nevada-extension-cable-3300-xl-series","title":"330130-035-00-00 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-035-00-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between eddy-current probes and Proximitor sensors within 3300 XL Machinery Protection Systems. This cable maintains the impedance characteristics of the tuned oscillation circuit, ensuring that the high-frequency signal remains undisturbed across the physical distance between the transducer and the monitoring electronics. The assembly provides mechanical and electrical connectivity for radial vibration and axial position measurement loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: 3300 XL Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-035\u003c\/strong\u003e: Cable length (3.5 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Connector\/Cable configuration (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval (Not required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-035-00-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.0 cm x 17.0 cm x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Signal transmission)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system requires precise eddy-current probe scaling to ensure accurate measurement of rotor dynamics. The extension cable is an integral part of the tuned circuit; therefore, impedance must be maintained. When integrating these components, technicians must implement rigorous cross-talk suppression by isolating signal paths from high-power electromagnetic sources. Proper gap voltage validation, targeting -10 VDC at the mid-linear range, remains the standard to confirm that cable impedance shifts have not introduced measurement bias or phase-angle errors.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330130-035-00-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation and compatibility documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Maintain a minimum separation of 30 cm (12 inches) from AC power lines to avoid induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Adhere to a minimum bend radius of 25.4 mm (1.0 inch) to prevent coaxial deformation and impedance variation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e: Ensure the ClickLoc connectors are fully seated and free of contaminants before mating to prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Utilize single-point grounding at the monitor panel to maintain signal integrity and avoid ground loops within the transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDelivery Information\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipped via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecurely packed in anti-static industrial packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used with non-XL 3300 series components?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3300 XL extension cable is backward compatible with non-XL 3300 series 5 mm and 8 mm transducer systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for ETR (Extended Temperature Range) applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile standard cables are rated to 177 deg C, the system allows the use of ETR probes with this cable; however, the component with the lowest rating limits the system's thermal envelope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the system length fixed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Proximitor is factory-calibrated for a specific total system length. Altering the cable length changes the circuit's resonant frequency and degrades data accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I identify cable damage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical damage to the coaxial insulation or a shield break will likely result in a NOT OK signal from the Proximitor due to impedance mismatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable require grounding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable shield must be grounded only at the monitor panel to prevent the formation of ground loops that could introduce signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 69.9 pF\/m capacitance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis value is the characteristic capacitance of the coaxial cable, which is critical for maintaining the tuned frequency of the eddy-current oscillation loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I solder the cable to repair a cut?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Any repair or splice alters the impedance of the tuned circuit and invalidates the factory calibration, leading to unusable measurement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the connectors protected during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the supplied protective caps during pulling through conduits to prevent debris or moisture from entering the connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026838769837,"sku":"330130-035-00-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--3_9e993ea5-dd4e-4dd9-933c-23b707f34cf1.jpg?v=1781084190","url":"https:\/\/www.maxwellplc.com\/products\/330130-035-00-00-bently-nevada-extension-cable-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}