{"product_id":"330130-030-02-05-bently-nevada-extension-cables-3300-xl","title":"330130-030-02-05 Bently Nevada Extension Cables 3300 XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330130-030-02-05 is a high-performance extension cable assembly engineered for the 3300 XL Proximitor Sensor System. As a critical link in the eddy-current transducer loop, this cable connects the proximity probe to the Proximitor sensor, ensuring the integrity of raw vibration and position signals. Engineered with a 75 Ohm coaxial architecture, the 330130-030-02-05 is designed to maintain signal fidelity in harsh industrial environments, including high-temperature zones and areas subject to significant oil mist and mechanical vibration. By utilizing Bently Nevada's proprietary ClickLoc connectors, the assembly provides a secure, vibration-resistant connection that minimizes signal attenuation and impedance mismatches, which are often the root cause of measurement errors in critical turbomachinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-030-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 25 x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop Signal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Miniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJacket Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluoroplastic (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 330130-030-02-05 part number is segmented to denote specific physical and environmental attributes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e030: Cable Length (3.0 meters) – Calibrated to match total loop requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Option (Miniature coaxial connector with protective connector option).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency Approval (Multiple agency compliance for hazardous area applications).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is utilized in diverse mechanical condition monitoring deployments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial Vibration Monitoring: Used in fluid-film bearings on steam and gas turbines to detect shaft orbit anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial Position (Thrust) Monitoring: Provides stable transmission for monitoring rotor position changes to prevent internal machine contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReciprocating Compressor Analysis: Supports high-frequency data collection for piston rod position and dynamic vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest Stand Instrumentation: Serves as a standard interface for validating the performance of newly assembled or overhauled rotating equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330130-030-02-05 is strictly compatible with the Bently Nevada 3300 XL 8 mm and 5 mm transducer systems. It is calibrated to integrate with the 3300 XL Proximitor Sensor and the corresponding proximity probe. Integration with older 3300-series hardware is not supported, as impedance characteristics and connector geometry are optimized specifically for the XL platform. Mixing this component with non-XL hardware will compromise the 200 mV\/mil scale factor, potentially leading to inaccurate alarm setpoints and unnecessary machine trips.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Handling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect all connectors for contaminants, dust, or metallic particles before mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManually engage the ClickLoc connectors until a distinct mechanical click is heard; do not use pliers or excessive force to tighten.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep protective thread caps on connectors until the moment of installation to prevent damage to the gold-plated pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCable Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum bend radius of 64 mm (2.5 inches) to prevent deformation of the internal cable geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlways route the cable through grounded metallic conduit to suppress EMI (Electromagnetic Interference) and to provide protection from physical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure that the cable is secured at appropriate intervals to prevent fatigue and chafing in high-vibration areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity through all connections to the instrument ground bus in the junction box or terminal cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid creating \"ground loops\" by ensuring the probe, cable, and monitor are referenced to the same instrumentation ground point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Fidelity: Low-loss coaxial design ensures high-frequency components of vibration signals are transmitted without attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure Connection: ClickLoc technology ensures that connections remain stable even in high-vibration environments where traditional threaded connectors might loosen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection: High-grade FEP jacket material provides superior resistance to hydrocarbons and extreme thermal cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Calibration: As an integral component of the 3300 XL system, this cable ensures that the transducer loop remains within factory-specified linearity and accuracy standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330130-030-02-05: 3.0 m Extension Cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded Items: Cable assembly, integral connectors, and connector protection caps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation: Each shipment includes standard installation documentation and regulatory compliance data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable assembly field-repairable if the connector is damaged?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The ClickLoc connectors are factory-terminated and calibrated. Damage to the cable or connector necessitates a complete replacement to maintain system accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this 3.0-meter cable with a 5-meter or 9-meter probe system?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The total system length (probe + extension cable) must match the calibration of the Proximitor sensor. Using the wrong length will invalidate the system linearity.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the temperature rating of 177 deg C apply to the entire cable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the cable and the connectors are rated for operation up to 177 deg C, making them suitable for most turbine and compressor bearing housing environments.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the impedance 75 Ohm instead of 50 Ohm?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Bently Nevada transducer systems utilize 75 Ohm coaxial cables to optimize signal-to-noise ratio and frequency response for eddy-current probe applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is it possible to use this cable without conduit?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: While physically possible, it is not recommended. Conduit is essential to shield the signal from external electromagnetic interference and to prevent accidental mechanical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify that the cable is functioning correctly after installation?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Measure the DC gap voltage at the monitor output. If the voltage is erratic or outside expected ranges during shaft rotation, check for cable shield continuity or loose connections.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the \"05\" agency approval suffix change the physical properties of the cable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The suffix pertains solely to regulatory certification for use in specific hazardous areas; the physical construction remains identical to standard versions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be exposed to water or steam?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The FEP jacket is chemical-resistant, but the connectors are not hermetically sealed. Ensure all connections are enclosed in a junction box to protect them from direct moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819360941,"sku":"330130-030-02-05","price":101.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-030-02-05-3300-xl-standard-extension-cable-utqj0m03bvg.jpg?v=1766979482","url":"https:\/\/www.maxwellplc.com\/products\/330130-030-02-05-bently-nevada-extension-cables-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}