{"product_id":"330106-05-30-10-02-05-05-bently-nevada-3300-xl-8mm-series-proximity-transducer","title":"330106-05-30-10-02-05-05 Bently Nevada 3300 XL 8mm Series Proximity Transducer","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330106-05-30-10-02-05-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330106\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for contactless eddy-current displacement measurements within 3500 and 3300 Machinery Protection Systems. Configured as a 3300 XL 8 mm proximity transducer, this physical hardware converts the relative dynamic or static distance between the probe tip and the monitored target shaft into a proportional electrical voltage signal for vibration and position evaluation.\u003c\/p\u003e\n\u003ch3\u003eOption Code Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330106\u003c\/strong\u003e: 3300 XL 8 mm Proximity Transducer (Standard M10 x 1 thread, unthreaded length option)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Unthreaded Length option (50 mm unthreaded portion on the probe sleeve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-30\u003c\/strong\u003e: Case Total Length option (30 mm threaded portion, total case length 80 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Total Length option (1.0 meter total integrated cable length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Connector Option (Miniature coaxial click-loc connector with fluid leakage protection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Agency Approval Option (Multiple CSA, ATEX, and IECEx intrinsic safety certifications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Material and Extension Cable Armor Option (Stainless steel flexible armor sleeve over the extension cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330106-05-30-10-02-05-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by external Proximitor Sensor (-24 VDC input bias)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when matched with target AISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils) starting at nominal calibration gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 standard ISO metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Eddy-Current Proximity Scaling\u003c\/h3\u003e\n\u003cp\u003eThis 3300 XL series transducer leverages high-frequency eddy-current probe scaling to convert structural micro-displacement into high-fidelity analog voltage output. For accurate asset health evaluation across fluid-film bearing machinery, gap voltage validation must hit -10 VDC targets at the center of the calibrated linear range. This electrical positioning matches the baseline potential needed by the 3500\/42M or 3500\/40M monitor modules to compute absolute shaft vibration without clipping. Proper electrical isolation and precise installation physical geometry guarantee cross-talk suppression when multiple 330106 probes are mounted within close proximity on the same radial bearing plane.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest \u0026amp; Kit Inclusions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Hardware\u003c\/strong\u003e: One (1) Bently Nevada 330106-05-30-10-02-05-05 armored eddy-current proximity probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Protection\u003c\/strong\u003e: Two (2) silicone connector protector boots for insulation from oily machine environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation\u003c\/strong\u003e: One (1) printed technical compliance slip and certificate of calibration conformance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFasteners\u003c\/strong\u003e: Two (2) matching M10 x 1 locknuts for structural case mounting and depth fixing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Thread Mounting \u0026amp; Connection Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure a minimum of five (5) full thread engagement turns when securing the M10 x 1 probe case into the bearing housing or brackets.\u003c\/li\u003e\n\u003cli\u003eRun a complete physical clear gap check before machine startup to verify that the probe tip will not strike the rotating shaft under high rotor dynamic deflection.\u003c\/li\u003e\n\u003cli\u003eFix the flexible stainless steel armored sleeve along static structures using rubber-lined clips to mitigate mechanical resonance damage or cable fatigue.\u003c\/li\u003e\n\u003cli\u003eKeep the coaxial click-loc connectors completely free of moisture, synthetic lubricants, and particulate matter prior to snapping the locking sleeve home.\u003c\/li\u003e\n\u003cli\u003eGround the outer coaxial shield exclusively at the Proximitor sensor housing panel terminal block to establish an effective single-point Faraday cage circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics \u0026amp; Package Handling Speed\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstimated Dispatch Window\u003c\/strong\u003e: Ships 2-7 days when payment finish through our logistics network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransit Carriers\u003c\/strong\u003e: Handled via global express networks including DHL, FEDEX, or UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructural Safety Provision\u003c\/strong\u003e: Dispatched in customized anti-static industrial packaging featuring multi-layered high-density shock-absorption foam.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Application FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the default output response profile if the probe tip contacts the target shaft?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical tip contact destroys the coil substrate, resulting in an open circuit loop that forces the external Proximitor sensor to output a fault level near 0 VDC, triggering a NOT OK status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 1.0 meter integrated cable probe connect directly to a 3500 monitoring rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this transducer requires a matching 3300 XL extension cable (typically 4.0 or 8.0 meters) and a dedicated 3300 XL Proximitor sensor to interface with standard input cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does ambient temperature shift alter the linear scale factor of the 330106 probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThermal drift is minimized by internal material compensation, maintaining total scale factor error within a tight envelope over the rated -52 deg C to +177 deg C operating band.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to mix this 3300 XL probe with older 3300 5mm or 7mm series extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMixing system generations disrupts electrical impedance matches, altering the 7.87 V\/mm scale factor and causing severe measurement errors across the linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions prevent signal cross-talk when installing pairs for X-Y radial vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum physical separation distance of 40 mm between adjacent 8 mm probe tips unless they are mounted at a true 90-degree orthogonal angular configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model support hot-swap replacement while the machine protection system is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe element is a passive inductive component and can be physically replaced or disconnected at the coaxial link without powering down the 3500 monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the critical target material requirement for the stated calibration metrics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard scale factor assumes an AISI 4140 steel target; alternative alloys change the magnetic permeability and demand custom Proximitor sensor recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the armored sleeve be handled during tight radius conduit bends?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe flexible stainless steel armor must not be bent past a minimum radius of 30 mm to avoid crushing internal coaxial insulation and changing cable capacitance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518845837485,"sku":"330106-05-30-10-02-05-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330106-05-30-10-02-05-05-proximity-transducer-34ffmq43yut.jpg?v=1766980298","url":"https:\/\/www.maxwellplc.com\/products\/330106-05-30-10-02-05-05-bently-nevada-3300-xl-8mm-series-proximity-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}