{"product_id":"330105-02-12-05-12-05-bently-nevada-3300-xl-8-mm-reverse-mount-probes","title":"330105-02-12-05-12-05 Bently Nevada 3300 XL 8 mm Reverse Mount Probes","description":"\u003cp\u003eConfigured for non-contacting static and dynamic shaft displacement measurements in 3300 XL Turbomachinery Instrumentation System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-05-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReverse Mount Probes) provides direct physical\/electrical execution. The component interacts via high-frequency eddy-current fields generated by the reverse-mount tip geometry facing a rotating conductive target to output raw radial vibration, axial position, or speed metrics.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02-12:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3\/8-24 UNF threads mechanization housing option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 meter (20 inches) total integrated cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature coaxial ClickLoc connector with fluid-resistant protective armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple Agency Approvals certification option (ATEX, IECEx, CSA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-05-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.0 x 22.0 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Mount Cylinder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Sensing Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBaseline Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Tracking\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm reverse-mount sensing tip relies on strict compliance with factory-calibrated eddy-current probe scaling constraints to output a linear voltage slope of 7.87 V\/mm. Mechanical positioning of the housing assembly defines the static air gap relative to the target surface, matching the gap voltage validation target of -10 VDC at the linear center point of the transducer system loop. This physical-to-electrical alignment enables continuous parsing of microscopic high-frequency rotor dynamics. Internal impedance optimization across the armored coaxial path preserves signal integrity and ensures cross-talk suppression when multiple probes are configured in close physical proximity along a single machinery bearing casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Package Composition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) integrated Bently Nevada 330105 8 mm reverse mount probe with 0.5-meter armored cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) fluorocarbon heat-shrink sleeve kit for external coaxial terminal insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcludes standalone 3300 XL Proximitor sensors, external extension cables, and dedicated rigid mounting brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Dispatch Standards\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispatches are finalized within 2-7 days when payment finish verification is cleared.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Methods:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsignments route through premium priority lines including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDefect Prevention Packaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll hardware travels enclosed within high-density anti-static industrial packaging to negate latent electrostatic or physical breakdown risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Mount Torquing Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThread the reverse mount sleeve housing manually into the mounting bracket or port. Torque the primary sleeve lock fasteners to a maximum limit of 11.2 N-m (100 in-lb) to prevent structural binding or thread distortion of the 3\/8-24 UNF interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Gap Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect a digital voltmeter to the corresponding Proximitor output terminal block. Rotate the probe body inside the housing until the real-time gap voltage validation records -10 VDC nominal before tightening the outer locking rings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Joint Shield Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to final insertion into protective conduit sleeves, wrap all miniature ClickLoc connection nodes with the provided fluorocarbon heat-shrink insulation. This isolates the coaxial signal path from local ground potentials and sustains cross-talk suppression integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does a field deviation from the nominal gap voltage validation affect target measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: Installing the probe face outside the calibrated linear window modifies the configured eddy-current probe scaling profile. This leads to early signal saturation or clipping during transient peaks, preventing accurate evaluation of complex rotor dynamics.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 0.5-meter armored integrated cable be cut or modified in the field to match short conduit runs?\u003c\/p\u003e\n\u003cp\u003eA: No. Modifying the integrated cable changes the calibrated electrical length and loop capacitance properties. Splicing disrupts the calibrated eddy-current probe scaling, rendering the transducer loop output invalid.\u003c\/p\u003e\n\u003cp\u003eQ: What separation distance must be maintained to achieve effective cross-talk suppression with the 3300 XL sensor?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum center-to-center separation distance of 40 mm between adjacent 8 mm probe tips. Positioning tips closer than this threshold allows their electromagnetic fields to overlap, causing signal beat frequencies that override cross-talk suppression circuits.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821261485,"sku":"330105-02-12-05-12-05","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-05-12-05-3300-xl-8-mm-reverse-mount-probes-zv4du5hyul2.jpg?v=1766979539","url":"https:\/\/www.maxwellplc.com\/products\/330105-02-12-05-12-05-bently-nevada-3300-xl-8-mm-reverse-mount-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}