{"product_id":"330104-06-12-10-02-00-bently-nevada-proximity-probe-3300-xl-series","title":"330104-06-12-10-02-00 Bently Nevada Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for high-frequency relative displacement monitoring in 3300 XL machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-06-12-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction. This hardware captures instantaneous gap distance variations between the probe tip and a conductive target, supplying a modulated radio frequency signal to the Proximitor sensor for data conditioning and analysis.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 3300 XL 8 mm Proximity Probe (Reverse Mount)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e06: Unthreaded Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Overall Case Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Type (Miniature coaxial ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency Approval (Not required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-06-12-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Eddy-Current Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330104 series utilizes reverse mount configuration, ideal for installations where the probe is mounted through the machine case from the inside. Achieving precision requires strict eddy-current probe scaling; the transducer must be adjusted to a nominal -10 VDC gap voltage target within the machine's operating range. Cross-talk suppression is maintained by observing physical separation distances between adjacent sensors to prevent interference in the 1 MHz carrier frequency. Rotor dynamics analysis is contingent upon maintaining this linear operation range to prevent waveform distortion.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-06-12-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Ensure the reverse mount jam nut is tightened to the specified torque to maintain probe position under load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSide-View Clearance: Ensure a minimum of 10 mm clearance from the mounting hole wall to avoid peripheral metal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route coaxial cables through dedicated grounded metallic conduit, separating signal lines from high-voltage AC cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Verify the ClickLoc coupling is fully seated; ensure the connector protector is secure to prevent moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Validation: Measure the output voltage at the Proximitor sensor terminal block to verify proper gap adjustment during site commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are 3300 XL probes interchangeable with legacy 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eA: No. 3300 XL probes are tuned specifically for the 3300 XL Proximitor sensor frequency response and cannot be interchanged with legacy systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the PPS probe tip withstand high-pressure fluid environments?\u003c\/p\u003e\n\u003cp\u003eA: The probe assembly is rated for operation in pressure environments up to 60 bar, provided proper O-ring sealing is utilized at the thread interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum allowable cable length for this probe?\u003c\/p\u003e\n\u003cp\u003eA: The system is factory-calibrated for a total system length of 5 or 9 meters. Deviating from these lengths impacts frequency response and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe case grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically isolated from the signal common. Proper system grounding must be verified according to the specific site wiring diagram.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe cable be field-terminated?\u003c\/p\u003e\n\u003cp\u003eA: No. Cutting or splicing the cable alters the system's characteristic impedance and resonant frequency, leading to inaccurate measurement output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a failed proximity probe?\u003c\/p\u003e\n\u003cp\u003eA: Failure typically presents as an open circuit or a hard-scale voltage reading (full negative or positive) at the Proximitor sensor output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the target material affect measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: Probes are calibrated for 4140 steel. Other conductive materials have different magnetic permeabilities and require specific scale factor adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 1 MHz carrier frequency?\u003c\/p\u003e\n\u003cp\u003eA: The 1 MHz frequency is optimized for eddy-current penetration depth in standard carbon steel to provide high-fidelity dynamic displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518827421869,"sku":"330104-06-12-10-02-00","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-06-12-10-02-00-3300-xl-8-mm-probes-2jjrzzxztyj.jpg?v=1766979751","url":"https:\/\/www.maxwellplc.com\/products\/330104-06-12-10-02-00-bently-nevada-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}