{"product_id":"330104-00-14-10-02-cn-bently-nevada-proximity-probes-3300-xl","title":"330104-00-14-10-02-CN Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eConfigured for signal acquisition in mechanical monitoring networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-14-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 8 mm Proximity Probe) provides direct physical transduction of rotor displacement. This hardware component translates the radial gap between the probe tip and a conductive surface into a high-frequency eddy-current signal, which is subsequently conditioned for vibration and position analysis within the 3300 XL monitoring platform.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-14-10-02-CN identification signifies the following mechanical and electrical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread: M10 x 1 (with integrated protective armor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded length: 0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverall case length: 140 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal system length: 1.0 meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Miniature coaxial ClickLoc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-14-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 22.4 cm x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 12 mA @ -24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure data integrity. During commissioning, gap voltage validation is performed to target approximately -10 VDC at the monitor input, which identifies the probe's optimal linear operational range. Accurate rotor dynamics analysis depends on effective cross-talk suppression; therefore, signal cabling must be segregated from high-current power lines to avoid induced EMI. Such shielding measures prevent the degradation of orbital waveforms and shaft centerline measurements caused by electromagnetic noise in the transducer loop.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104-00-14-10-02-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard lock nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Stability: Secure the probe using a minimum of 5 full thread turns of engagement to ensure the unit remains rigid under machine operational vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Requirements: The armored cable should be routed through grounded metallic conduit to provide shielding against external interference and physical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance Limits: Ensure a radial clearance of 3 probe tip diameters from nearby metal structures to prevent measurement field distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Utilize manual pressure to seat ClickLoc connectors; the use of torque tools is prohibited to prevent damage to the internal contact pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponents are sealed in anti-static industrial packaging to prevent electrostatic discharge and impact damage during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material targets are supported? The system is factory-calibrated for AISI 4140 steel. Any deviation in the magnetic permeability or electrical resistivity of the target material necessitates a site-specific scale factor adjustment to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the probe sensitivity? The 3300 XL system, when configured with this probe, maintains a fixed sensitivity of 7.87 V\/mm (200 mV\/mil) within the defined linear operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow often should calibration be verified? Calibration verification is required during machine turnarounds or if the monitoring instrumentation reports persistent drift in the baseline gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe operate in hazardous environments? This model is designed for use in hazardous locations only when installed in accordance with site-specific intrinsic safety control drawings and designated barrier requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat extension cables are compatible? Only Bently Nevada 3300 XL extension cables are compatible. Impedance mismatches resulting from the use of non-specified cabling will induce signal reflection and erroneous vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes unstable gap voltage? Unstable signals are typically caused by compromised cable shielding, loose mechanical connections at the probe bracket, or high levels of shaft mechanical runout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is probe health tested? Health is assessed by measuring the static loop resistance and verifying the dynamic signal frequency response using a calibrated transducer shaker or simulator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the expected service life? Service life is defined by the thermal and mechanical duty cycles of the site. Under stable conditions, the unit is rated for continuous, long-term operational support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026785423533,"sku":"330104-00-14-10-02-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--4_81dc675a-9a15-4b0e-a400-4bf272e4f6f0.jpg?v=1780477644","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-14-10-02-cn-bently-nevada-proximity-probes-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}