{"product_id":"330104-00-13-10-02-05-bently-nevada-proximity-probes-3300-xl","title":"330104-00-13-10-02-05 Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eConfigured for precision displacement measurement in mechanical monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-13-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 8 mm Proximity Probe) provides direct physical signal acquisition via an eddy-current transduction circuit. This sensor system converts the relative gap between the probe tip and a conductive metallic target into a proportional electrical signal, enabling the monitoring of shaft vibration and position within rotating equipment platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-13-10-02-05 identification corresponds to the following technical configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread: M10 x 1 (with integrated armor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded length: 0 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverall case length: 130 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal system length: 1.0 meter (3.3 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector\/Cable: Miniature coaxial ClickLoc standard cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproval: CSA, ATEX, IECEx.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-13-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 22.4 cm x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 12 mA @ -24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system utilizes eddy-current sensing where the probe functions as the primary inductive element in the measurement loop. Accurate rotor dynamics analysis depends on precise probe scaling and gap voltage validation, which must be verified to target -10 VDC at the monitor input for optimal linear range operation. Signal integrity is maintained through effective cross-talk suppression by ensuring adequate spatial separation between probes. Operators must avoid routing probe leads adjacent to high-power AC conductors, as induced electromagnetic noise can distort vibration waveforms and shaft centerline positioning data.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104-00-13-10-02-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation instruction set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLocking nuts (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Mount the probe into a rigid, non-conductive, or grounded bracket. Ensure a minimum of 5 full thread turns of engagement to guarantee mechanical stability under operational vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Shielding: Route the armored coaxial cable through a grounded metallic conduit to prevent environmental RFI\/EMI interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTarget Clearance: Maintain a radial clearance of at least 3 probe tip diameters from nearby metal to prevent measurement field distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Procedure: Fasten the ClickLoc connectors using finger-tight pressure; mechanical tools should not be utilized to prevent damage to the internal contact pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispatched via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComponents are provided in anti-static industrial packaging to prevent electrostatic discharge and mechanical impact during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material targets are supported? The transducer system is factory-calibrated for AISI 4140 steel. Using target materials with different magnetic or electrical properties requires a field-derived scale factor correction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the probe sensitivity? This system maintains a standard sensitivity of 7.87 V\/mm (200 mV\/mil) provided the total loop impedance remains within design parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow often should calibration be verified? Verification of loop health and signal response is advised during routine machine outages or if the monitoring system logs consistent baseline drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe operate in hazardous environments? This model is suitable for hazardous area use when part of an installation approved by site-specific control drawings and intrinsic safety barrier requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat extension cables are compatible? Only Bently Nevada 3300 XL series extension cables are compatible. Impedance mismatches caused by non-compliant cabling result in signal attenuation and inaccurate displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes unstable gap voltage? Instability usually stems from loose mounting fixtures, damaged coaxial cable shielding, or mechanical runout observed on the monitored shaft surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is probe health tested? Health is assessed by measuring the static DC loop resistance and validating the dynamic signal output at the monitor rack using a calibrated transducer simulator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the expected service life? Service life is subject to operational thermal and mechanical stress. Under standard industrial conditions, the probe is rated for long-term continuous duty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026838114477,"sku":"330104-00-13-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian_3_db42956c-5134-48a2-9d6f-588ad34c51bf.jpg?v=1780477576","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-13-10-02-05-bently-nevada-proximity-probes-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}