{"product_id":"330104-00-12-10-02-00-bently-nevada-proximity-probes-3300-xl-series","title":"330104-00-12-10-02-00 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-12-10-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3500 Machinery Protection System platforms. It transforms micro-level mechanical shaft movements into corresponding electrical voltage variables processed continuously by monitoring hardware units.\u003c\/p\u003e\n\u003ch3\u003ePart Number Option Suffixes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, reverse mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option (0 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-12\u003c\/strong\u003e: Overall case length option (120 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Total length option (1.0 m \/ 3.3 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Miniature coaxial clickloc connector with connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval option (No approvals required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-12-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.0 cm x 18.0 cm x 5.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer component driven by Proximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe reverse-mount 8 mm sensor probe maps mechanical shaft tracking through precise eddy-current probe scaling configurations. Operational execution requires exact gap voltage validation (-10 VDC targets) representing the definitive geometric center of the linear voltage window. When configuring multi-plane rotor dynamics instrumentation layout, field technicians must strictly adhere to proximity spacing minimums to ensure absolute cross-talk suppression. Overlapping radio frequency field zones between adjacent probe tips alter magnetic flux performance, introducing voltage errors into the monitoring unit.\u003c\/p\u003e\n\u003ch3\u003eKit Packaging Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330104-00-12-10-02-00 Reverse Mount Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Prefitted miniature coaxial clickloc male connector terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Removable external silicone connector protector sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Field hardware manual sheet containing structural loop profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Mount Thread Engagement\u003c\/strong\u003e: Turn the metric M10 x 1 threaded sleeve into the probe holder assembly by hand to verify smooth alignment before tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Voltage Setpoint\u003c\/strong\u003e: Advance or retract the probe body within the sleeve while tracking the raw signal loop until achieving the target value of -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Cable Management\u003c\/strong\u003e: Secure the 1.0 m flexible integral lead inside heavy conduit paths to insulate the coaxial jacket against friction and physical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Isolation\u003c\/strong\u003e: Prevent the outer braided shield from grounding against intermediate machine housings; terminate the shield layer solely at the Proximitor block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransit and Dispatch Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLogistics Window: 2-7 days when payment finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistribution Carrier: Sent internationally via express premium priority lines through DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Measures: Enclosed within specialized anti-static industrial packaging configured for drop protection and static shield isolation during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Queries \u0026amp; Answers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific electrical parameter signifies that the probe gap is correctly calibrated?\u003c\/p\u003e\n\u003cp\u003eThe electrical field calibration requires adjusting the sensor position until the raw DC voltage at the Proximitor reads -10 VDC, securing the exact midpoint of the linear displacement zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe component be hot-swapped while the machinery monitor is under power?\u003c\/p\u003e\n\u003cp\u003eYes, the probe is a passive transducer and can be decoupled from the cable link while live. However, the sudden voltage drop will trigger rack alarms if bypass locks are not set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does targeting alternative metal substrates affect the factory scale factor?\u003c\/p\u003e\n\u003cp\u003eThe internal eddy-current loop is calibrated exclusively for AISI 4140 steel targets. Testing alternative metals changes the magnetic flux properties, introducing significant scaling calculation errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific industrial protection does the -02 connector option provide to the terminal link?\u003c\/p\u003e\n\u003cp\u003eThe -02 option designates a specialized connector protector that encapsulates the clickloc interface, preventing fluid ingress from lubrication oil, moisture, or aggressive chemical vapours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this hardware module draw direct operational current from the monitoring rack backplane?\u003c\/p\u003e\n\u003cp\u003eNo, the probe contains no active electrical components. It acts as a passive reactive load driven entirely by high-frequency excitation voltage generated by the external Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical spacing is mandatory to ensure complete cross-talk suppression between probes?\u003c\/p\u003e\n\u003cp\u003eProbes must maintain a minimum physical distance equivalent to at least three tip diameters from any adjacent probe or unexpected structural metal to preserve magnetic field integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat performance issue occurs if the total cable length is modified outside of specifications?\u003c\/p\u003e\n\u003cp\u003eThe system demands a matching 5.0 m or 9.0 m total system length. Arbitrary cable cutting or extensions throw off the tuned loop impedance, which invalidates the 7.87 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical temperature boundaries governing the probe tip and internal wire?\u003c\/p\u003e\n\u003cp\u003eThe 8 mm tip structure and matching coaxial lead are structurally rated to withstand field conditions ranging from a minimum of -51 deg C up to a maximum limit of +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518849638573,"sku":"330104-00-12-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-12-10-02-00-3300-xl-8-mm-probe-1rzwfquxd3b.jpg?v=1766980403","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-12-10-02-00-bently-nevada-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}