{"product_id":"330104-00-08-50-01-05-bently-nevada-proximity-probes-3300-xl-series","title":"330104-00-08-50-01-05 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-08-50-01-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104-00-08-50-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes, operates as a dedicated hardware component for non-contacting displacement measurement within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330104-00-08-50-01-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: 3300 XL 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Suffixes define probe physical length, mounting thread specifications, connector type, and cable armor requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-08-50-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 15 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer \/ Oscillator-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI Mechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm transducer system utilizes eddy-current probe scaling to convert shaft motion into a standardized output signal. During commissioning, gap voltage validation against -10 VDC targets is required to ensure the probe remains within its linear range relative to the monitored surface. The system maintains stable rotor dynamics monitoring through precise radio-frequency oscillation. Cross-talk suppression is achieved by utilizing factory-tuned frequencies assigned to specific transducer channels, ensuring that adjacent probes do not induce signal interference in multi-channel monitoring racks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330104-00-08-50-01-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting: Install the probe into the threaded machine casing; adjust the physical gap using a feeler gauge to align with the -10 VDC gap voltage target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Handling: Route the factory-terminated coaxial cable through grounded metallic conduit; adhere to the minimum bend radius requirements to prevent cable damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the probe body to the machine frame to establish a singular, reliable electrical reference for the eddy-current field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Care: Maintain clean, dry, and secure coaxial connections; verify that all threaded connections are hand-tightened and free of debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Verification: Conduct a static gap voltage test using a high-impedance voltmeter at the Proximitor output terminals before initiating rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 330104 probe compatible with 3300 XL 5 meter or 9 meter system lengths?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the probe is integrated with the matching oscillator and extension cable calibrated for the intended total system loop length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I perform a gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA: Measure the output voltage at the Proximitor terminal block with a high-impedance digital multimeter while the probe is at a known physical distance from the target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the coaxial cable be field-terminated or spliced?\u003c\/p\u003e\n\u003cp\u003eA: No, field-splicing the coaxial cable changes the electrical resonance of the transducer system, which renders the factory-calibrated scale factor inaccurate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What effect does shaft material have on probe output?\u003c\/p\u003e\n\u003cp\u003eA: Sensitivity is calibrated for standard 4140 steel; other materials require a scaling factor adjustment to ensure displacement data remains accurate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the cable armor?\u003c\/p\u003e\n\u003cp\u003eA: Cable armor provides mechanical protection against debris, oil, and potential physical damage encountered in industrial rotating equipment environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the probe require an external power supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the probe is a passive device; it receives excitation power via the radio-frequency signal generated by the matched 3300 XL oscillator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the cause of an unstable or erratic gap signal?\u003c\/p\u003e\n\u003cp\u003eA: Erratic signals often result from loose connectors, electromagnetic interference, insulation damage on the coaxial cable, or target surface irregularities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is thread locking compound recommended for probe installation?\u003c\/p\u003e\n\u003cp\u003eA: No, thread locking compounds or heavy sealants can interrupt the electrical ground path between the probe body and the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823129261,"sku":"330104-00-08-50-01-05","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-08-50-01-05-3300-xl-8-mm-proximity-probes-bgu4wou3hea.jpg?v=1766979613","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-08-50-01-05-bently-nevada-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}