{"product_id":"330104-00-05-05-01-00-bently-nevada-3300-xl-series-proximity-probes","title":"330104-00-05-05-01-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting shaft displacement and vibration measurements in machinery protection loops, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-05-05-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length (0 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Overall case length (50 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Total length (0.5 m \/ 1.6 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Miniature coaxial ClickLoc connector, fluid-resistant boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: No regional hazardous area approvals requested\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parametric Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-05-05-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.0 cm x 18.0 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive element (driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) from target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when integrated into a 3300 XL 5-meter or 9-meter system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel (standard calibration target)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe employs high-frequency eddy-current fields to track high-speed rotor dynamics without mechanical contact. To establish accurate steady-state operation within the linear range, the field engineer must execute a physical gap voltage validation. Adjusting the probe's mechanical position relative to the target surface yields a baseline target value of -10.0 VDC at the Proximitor output terminal. This value represents the geometric center of the linear sensor slope. Proper installation pitch ensures optimal signal-to-noise ratios during high-amplitude shaft vibrations and prevents measurement saturation near the physical extremities of the probe's eddy-current field.\u003c\/p\u003e\n\u003ch3\u003eComponent Package Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330104-00-05-05-01-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x M10 x 1 Hexagonal locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Coaxial connector silicone insulation boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory conformance validation document packet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMechanical installation requires precise physical alignment to ensure the eddy-current field is not constrained. The probe tip must clear surrounding counterbore walls by a minimum diameter of 16 mm to avoid side-wall cross-talk and calibration errors. Use a calibrated handheld digital multimeter to monitor the DC gap voltage in real-time while threading the probe into its mounting bracket. Once the -10.0 VDC target voltage is logged, secure the M10 locknuts to the specified torque limit to prevent backing out during high-frequency machine operation. The miniature coaxial ClickLoc connector must be clean, dry, and clicked firmly together before being sealed inside the fluid-resistant boot. All field extension cabling must track through dedicated, grounded metal conduit, respecting a minimum bend radius of 25.4 mm.\u003c\/p\u003e\n\u003ch3\u003eLogistic and Freight Specifications\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, handled exclusively through DHL\/FEDEX\/UPS express networks. Hardware is shipped inside heavy-duty anti-static industrial packaging containing multi-layered ESD shielding film and customized structural low-density polyethylene foam cells to isolate the ceramic tip assembly and the flexible 0.5-meter coaxial cable from mechanical impact and transient electrostatic discharge during air transit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens to the proximity measurement if the target shaft material is not AISI 4140 steel?\u003c\/p\u003e\n\u003cp\u003eA: The eddy-current probe scaling will shift because different alloys have distinct magnetic permeability and electrical conductivity profiles. This change alters the standard 7.87 V\/mm scale factor, requiring laboratory recalibration or monitoring software compensation curves.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.5-meter total length probe connect directly to a TSI monitor panel without an extension cable?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 XL 8 mm proximity probe requires a matching extension cable to construct a complete electrical resonant loop. The combined length of the probe and extension cable must precisely equal the 5.0-meter or 9.0-meter specifications mandated by the Proximitor Sensor model in use.\u003c\/p\u003e\n\u003cp\u003eQ: Will disconnecting the ClickLoc connector while the monitor loop is energized damage the probe?\u003c\/p\u003e\n\u003cp\u003eA: No physical damage occurs to the passive probe element during a live disconnect. However, breaking the coaxial connection causes an immediate open-circuit state, driving the Proximitor output to a positive saturation voltage, which triggers a \"Not OK\" fault condition on the safety monitor module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823391405,"sku":"330104-00-05-05-01-00","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-05-05-01-00-3300-xl-8-mm-probe-lkjsnnqiajk.jpg?v=1766979621","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-05-05-01-00-bently-nevada-3300-xl-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}