{"product_id":"330104-00-04-10-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330104-00-04-10-02-00 Bently Nevada 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting vibration and displacement measurement in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-04-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. The hardware translates mechanical shaft position variations relative to the probe tip into proportional electrical signals via eddy-current field interaction, interfacing directly with the 3500 series monitoring racks or equivalent transducers.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option (0.0 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-04\u003c\/strong\u003e: Overall case length option (4.0 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Total length option (1.0 meter \/ 3.3 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Connector option (Miniature coaxial ClickLoc connector with connector protector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval option (No approvals required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-04-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mm x 150 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDriven by external Proximitor Sensor (Typically -24 VDC supply voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), beginning at approximately 0.25 mm (10 mils) from the target face\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) within nominal linear range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Target Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe relies on precise eddy-current probe scaling to ensure linear voltage output over the specified displacement envelope. During mechanical calibration, engineers must perform gap voltage validation targeting a nominal -10 VDC baseline, corresponding to the electrical center of the 80 mil linear window. Minimizing cross-talk suppression between adjacent probe installations requires maintaining a physical separation distance of at least 40 mm between probe tips when mounted parallel. Misalignment or incorrect cross-talk control compromises rotor dynamics analysis accuracy, injecting false signals into high-speed shaft observation loops.\u003c\/p\u003e\n\u003ch3\u003eComponent Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330104-00-04-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Coaxial Connector Protector (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x 3\/8-24 UNF Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory Calibration Data Validation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Installation Instructions\u003c\/h3\u003e\n\u003cp\u003eProper physical deployment requires verification of the unthreaded and total case length matching the machine casing configuration.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe body into the mounting bracket or stater block until the tip contacts the observed shaft surface, then back off the probe to establish the physical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor the electrical gap using a digital multimeter attached to the Proximitor Sensor output terminals. Adjust probe depth until the gap voltage registers -10.0 VDC (+\/- 0.5 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the position by tightening the provided hex jam nuts to a torque value not exceeding 4.5 N-m (40 in-lb) to prevent case deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 1.0 meter integral extension cable using conduit or dedicated cable trays. The coaxial run must maintain isolation from structural ground to eliminate ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eLogistics \u0026amp; Distribution Management\u003c\/h3\u003e\n\u003cp\u003eEstimated dispatch timeline is 2-7 days when payment finish. Dispatch execution proceeds via global couriers including DHL, FEDEX, and UPS. All units are shipped inside anti-static industrial packaging complete with shock-absorbent micro-cellular foam inserts to preserve calibration integrity during international transport.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mechanical limitation regarding extension cable length for this probe?\u003c\/p\u003e\n\u003cp\u003eA: The 330104-00-04-10-02-00 specifies a 1.0 meter total length. It must be paired exclusively with a 4.0 meter extension cable to establish a matched 5.0 meter system, or an 8.0 meter extension cable for a 9.0 meter system, depending on the Proximitor configuration. Altering cable length alters loop impedance and invalidates the 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be hot-swapped while the monitoring rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The probe itself is a passive inductive device powered by the Proximitor Sensor. Disconnecting or reconnecting the ClickLoc coaxial connector while the 3500 system is active does not cause electrical damage, though it will trigger a channel fault \/ NOT OK alarm on the monitoring rack.\u003c\/p\u003e\n\u003cp\u003eQ: How does material composition variations affect the factory calibration?\u003c\/p\u003e\n\u003cp\u003eA: The probe is calibrated at the factory for AISI 4140 steel targets. If used with alternative rotor materials such as 304 or 316 stainless steel, the eddy-current probe scaling shifts significantly, necessitating custom recalibration or the use of specific material correction multipliers within the monitoring software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518832795821,"sku":"330104-00-04-10-02-00","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-04-10-02-00-3300-xl-8-mm-proximity-probes-rxic0wberyc.jpg?v=1766979905","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-04-10-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}