{"product_id":"330104-00-04-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe","title":"330104-00-04-05-02-00 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eBently Nevada 330104-00-04-05-02-00\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330104\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting static and dynamic shaft displacement measurements across 3300 XL Turbomachinery Instrumentation System platforms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware measures high-frequency eddy-current field variations generated by the tip assembly interacting with a rotating conductive target to provide raw radial vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eshaft position,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor speed data.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Options \u0026amp; Structural Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e00 (Unthreaded Length Suffix):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e04 (Overall Case Length Suffix):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e40 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e05 (Total Length Suffix):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 meter (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 feet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e02 (Connector Style Suffix):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMiniature coaxial click-lock connector,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estandard cable type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e00 (Agency Approval Suffix):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNo approvals required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eMechanical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-04-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 x 15.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Thread Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1 Metric Thread Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Sensing Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eEddy-Current Probe Scaling and Rotor Dynamics Tracking\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 8 mm metric sensing tip relies on strict compliance with factory-calibrated eddy-current probe scaling constraints to output a linear voltage slope of 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e87 V\/mm.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMechanical positioning via the M10 x 1 threaded casing defines the static air gap,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ematching the gap voltage validation target of -10 VDC at the linear center point of the transducer system loop.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis physical-to-electrical alignment enables continuous parsing of microscopic high-frequency rotor dynamics.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal impedance optimization across the coaxial path preserves signal integrity and ensures cross-talk suppression when dual probes are configured in orthogonal X-Y arrangements on a single machinery bearing housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTransducer Unit Pack:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes the 330104 8 mm probe assembly with integrated 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5-meter standard cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInsulation Kit:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes standard fluorocarbon heat-shrink sleeve tubes for external coaxial joint isolation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Requirements:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAssociated 3300 XL Proximitor drivers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eextension lines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand installation brackets are omitted from this package and must be obtained separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eProcurement Logistics Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDispatch Window:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConsignments are processed for transfer within 2-7 days when payment finish sequences register.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCarrier Methods:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFreight delivery is executed via international priority lines including DHL,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFEDEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor UPS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Shielding:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eComponents travel enclosed inside static-shielding anti-static industrial packaging to mitigate electromagnetic or physical damage during transit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Torque Limits:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThread the probe barrel manually into the bracket or housing block.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTorque the primary locknuts to a maximum value of 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 N-m (45 in-lb) to prevent structural binding or stripping of the M10 x 1 threads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Gap Optimization:\u003c\/strong\u003e\u003cspan\u003e Connect a digital voltmeter to the Proximitor sensor output loop terminals.\u003c\/span\u003e\u003cspan\u003e Adjust the probe insertion depth relative to the target face until the real-time gap voltage validation reads exactly -10 VDC nominal before securing the jam nut.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Grounding:\u003c\/strong\u003e\u003cspan\u003e Keep the miniature click-lock connectors completely clean and dry during routing.\u003c\/span\u003e\u003cspan\u003e Insulate the connector joint with fluorocarbon heat-shrink sleeves to prevent grounding against local flexible conduit walls,\u003c\/span\u003e\u003cspan\u003e maintaining cross-talk suppression.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e How does an installation deviation from the nominal gap voltage validation affect vibration data?\u003c\/span\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e Placing the probe tip outside the calibrated linear zone alters the baseline eddy-current probe scaling factor.\u003c\/span\u003e\u003cspan\u003e This cause leads to signal clipping during high-amplitude transient events,\u003c\/span\u003e\u003cspan\u003e resulting in degraded accuracy when tracking high-frequency rotor dynamics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Can the 0.\u003c\/span\u003e\u003cspan\u003e5-meter integrated cable be cut or modified to simplify physical routing?\u003c\/span\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e No.\u003c\/span\u003e\u003cspan\u003e Altering the physical length of the integral cable changes the tuned loop capacitance and electrical length parameters.\u003c\/span\u003e\u003cspan\u003e Splicing disrupts the calibrated eddy-current probe scaling matrix,\u003c\/span\u003e\u003cspan\u003e completely invalidating the system calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What separation distance must be maintained to achieve effective cross-talk suppression?\u003c\/span\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e Maintain a minimum center-to-center separation distance of 40 mm between adjacent 8 mm probe tips.\u003c\/span\u003e\u003cspan\u003e Positioning tips closer than this threshold allows their electromagnetic fields to overlap,\u003c\/span\u003e\u003cspan\u003e causing signal beat frequencies that override cross-talk suppression circuits.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821851309,"sku":"330104-00-04-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-04-05-02-00-3300-xl-8mm-proximitor-probe-xpxomuw20vo.jpg?v=1766979562","url":"https:\/\/www.maxwellplc.com\/products\/330104-00-04-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}