{"product_id":"330103-13-23-05-02-00-bently-nevada-proximity-probe-3300-xl-8-mm-series","title":"330103-13-23-05-02-00 Bently Nevada Proximity Probe 3300 XL 8 mm Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-040-12-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between proximity probes and Proximitor sensors within 3300 XL Machinery Protection Systems. This high-frequency coaxial cable maintains precise system impedance required to preserve the linear transfer function of the eddy-current measurement chain. By providing a fixed electrical path, the cable ensures that probe gap voltage data is delivered to the Proximitor without attenuation or signal distortion, enabling accurate interpretation of shaft displacement, vibration, and rotor position.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: 3300 XL Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-040\u003c\/strong\u003e: Cable length (4.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-12\u003c\/strong\u003e: Connector\/Cable option (Standard connector with protective armor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency Approval option (Multiple international certifications)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-040-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 25.0 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance matched)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCombined probe and cable must equal 5.0 m or 9.0 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Impedance Matching\u003c\/h3\u003e\n\u003cp\u003eBently Nevada proximity systems rely on precise impedance matching across the probe, extension cable, and Proximitor sensor. The 330130 extension cable is manufactured to strict tolerance standards to prevent signal reflections that could corrupt the eddy-current probe scaling. Successful implementation requires that the combined system length (probe plus extension cable) strictly adheres to the 5.0 meter or 9.0 meter factory calibration. Any deviation from these fixed lengths introduces measurement errors in the rotor dynamics data. Furthermore, practitioners must ensure proper cross-talk suppression by keeping cable runs physically separated from high-voltage lines, which prevents electromagnetic interference from manifesting as ghost vibration signatures.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330130-040-12-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) protective connector sleeves (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical specification and compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e: Do not exceed a bend radius of 25.4 mm (1.0 inch) to avoid damaging the coaxial structure and altering cable impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e: Ensure the silicone connector protector is fully seated over the mated Click-Loc connections to prevent moisture and oil ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Utilize dedicated conduits or trays for signal cables; avoid high-vibration areas where the cable could experience mechanical fatigue or \"cable whip.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the cable shield is not inadvertently grounded to the machine frame at intermediate points; the shield should only reach ground potential at the monitor rack terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogistics \u0026amp; Transit\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipped via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-static industrial packaging used to prevent ESD and impact damage during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be cut to a different length in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Cutting or splicing the cable alters the characteristic impedance, which invalidates the factory calibration and degrades measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the extension cable is healthy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse an ohmmeter to check for continuity of the center conductor and ensure there is no short-circuit between the center conductor and the shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Armor\" option in the suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe armor option provides a flexible stainless steel conduit over the coaxial cable, protecting it from mechanical damage, abrasion, and harsh chemical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the connector type affect signal transmission?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Click-Loc connector is designed for a secure, vibration-resistant connection. It ensures low-resistance contact for the sensitive high-frequency signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix cables of different lengths?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly if the total system length (Probe + Extension Cable) sums to either 5.0 meters or 9.0 meters. These are the only two lengths calibrated by the manufacturer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes signal drift in the extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSignal drift is often caused by thermal expansion of the cable or degradation of the connector due to oil or water ingress. Keep connectors clean and dry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the system react to an open extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor will detect an open circuit in the oscillation loop and trigger a NOT OK fault, resulting in a loss of valid displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this cable with non-XL series sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. 3300 XL components are designed specifically for the XL system architecture. Mismatching components will result in inaccurate readings and system faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518843183277,"sku":"330103-13-23-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-13-23-05-02-00-3300-xl-8-mm-proximity-probes-55payikcrvm.jpg?v=1766980243","url":"https:\/\/www.maxwellplc.com\/products\/330103-13-23-05-02-00-bently-nevada-proximity-probe-3300-xl-8-mm-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}