{"product_id":"330103-00-25-10-02-00-bently-nevada-3300-xl-proximity-probe","title":"330103-00-25-10-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for high-speed displacement measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-25-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103-00-25-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Probe) provides direct physical execution of eddy-current distance sensing within turbine monitoring (TSI) systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330103-00-25-10-02-00 follows the standardized Bently Nevada 3300 XL naming convention:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103: 8 mm probe with internal armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded length (0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25: Case length (250 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector type (connector without housing).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval (none required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-25-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 x 25.0 x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe probe operates on the eddy-current principle, requiring precise probe scaling to maintain linear output over the intended range. Accurate gap voltage validation is a requirement for commissioning, with a target operational setpoint of -10 VDC to ensure the probe remains in the linear region of the transducer curve. The 3300 XL system incorporates effective cross-talk suppression, ensuring that adjacent probes in multi-channel configurations do not interfere with vibration data. These modules are used to monitor rotor dynamics, detect shaft centerline position, and identify radial vibration signatures in high-velocity industrial machinery.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330103-00-25-10-02-00 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective tip cover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation and technical compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Extension cables and Proximitor sensors are sold separately and must be impedance-matched to the 3300 XL transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Interface: Install the probe in a rigid, vibration-resistant bracket; ensure the probe tip is perpendicular to the shaft target area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Use a depth micrometer to set the mechanical gap; confirm the Proximitor output voltage reaches the -10 VDC target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Secure the armored coaxial lead away from high-current conductors and rotating components to prevent EMI and mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection: Ensure coaxial connectors are clean and fully seated; use a straight-line force until the click-loc mechanism is engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread Management: Verify that jam nuts are secured to prevent movement due to machine vibration, without exceeding torque limits of the housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal operating gap voltage for this model?\u003c\/p\u003e\n\u003cp\u003eThe nominal operating gap is centered at -10 VDC, which corresponds to the mid-point of the linear sensing range for the 3300 XL 8 mm system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the internal armor be removed to increase flexibility?\u003c\/p\u003e\n\u003cp\u003eNo. The armor is an integral part of the probe assembly, providing mechanical protection; removing it compromises the probe's integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage drifts from -10 VDC?\u003c\/p\u003e\n\u003cp\u003eIf the voltage drifts significantly, the probe may be approaching its non-linear sensing limits, which will degrade the accuracy of vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific target material for calibration?\u003c\/p\u003e\n\u003cp\u003eThe standard calibration is for 4140 steel. If the rotor shaft material differs, a scale factor adjustment or custom calibration curve is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the 250 mm case length utilized?\u003c\/p\u003e\n\u003cp\u003eThe 250 mm length allows for installation in deep-recessed mounting locations where shorter probes cannot reach the sensing target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this probe with an older 3300 series Proximitor?\u003c\/p\u003e\n\u003cp\u003eWhile the connector may be physically compatible, the 3300 XL system should be used as a matched set (Probe, Extension Cable, Proximitor) for guaranteed accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is a short circuit in the cable detected?\u003c\/p\u003e\n\u003cp\u003eA short circuit often presents as a fixed voltage (0 VDC) or a erratic signal drift that fails the diagnostic checks in the monitoring rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum bend radius for the cable?\u003c\/p\u003e\n\u003cp\u003eThe armored cable is designed for durability, but it should not be bent sharper than its specified radius to avoid internal damage to the coaxial dielectric.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518841053357,"sku":"330103-00-25-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-25-10-02-00-3300-xl-8-mm-proximity-probes-o0sjjbjn4rd.jpg?v=1766980231","url":"https:\/\/www.maxwellplc.com\/products\/330103-00-25-10-02-00-bently-nevada-3300-xl-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}