{"product_id":"330103-00-16-10-12-05-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-16-10-12-05 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for signal transmission between proximity probes and monitoring instrumentation in 3300 XL Series systems, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"122\"\u003eBently Nevada 330103-00-16-10-12-05\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"159\"\u003e330103\u003c\/b\u003e Extension Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Configuration Matrix\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe assembly follows the standard 3300 XL nomenclature:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e330103: Base Model (Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e00: Unarmored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e16: 1.6 meters length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e10: Connector protector kit included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e12: Miniature coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e05: Agency approval option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"9\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,1,0\"\u003e330103-00-16-10-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,1,0\"\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,1,0\"\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,1,0\"\u003e25 cm x 25 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,1,0\"\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,1,0\"\u003ePassive (Impedance matching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,0,0\"\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,1,0\"\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,0,0\"\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,1,0\"\u003e0 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eEddy-Current Transducer Performance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe cable assembly maintains the 50 Ohm system impedance required for the 3300 XL transducer system to ensure accurate eddy-current probe scaling. This component facilitates precise gap voltage validation, targeting -10 VDC at the monitor input. Shielded construction provides cross-talk suppression, maintaining signal integrity required for rotor dynamics analysis. Insertion loss is controlled to prevent deviations in displacement measurement sensitivity during high-speed rotating machinery monitoring.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e1 x 330103-00-16-10-12-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e1 x Connector Protector Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e1 x Safety and Installation Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eRouting\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,1,0,0\"\u003eInstall within rigid or flexible conduit to protect the coaxial jacket from mechanical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,1,1,0\"\u003eAdhere to a minimum bend radius of 25 mm to prevent dielectric deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eTermination\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,1,0,0\"\u003eClean all connector interfaces using a non-residue electronic cleaner prior to mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,1,1,0\"\u003eTighten connectors by hand to ensure consistent electrical contact and maintain shielding continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eGrounding\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,1,0,0\"\u003eEnsure the transducer mounting assembly provides a low-impedance ground path to the machine casing to prevent ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eCan this cable be used for legacy probe systems?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eThis cable is specifically designed for 3300 XL transducer systems to maintain a 50 Ohm characteristic impedance. Use with other systems may cause calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eIs it possible to splice this cable to increase length?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eNo. Modifying the cable length alters the impedance and capacitance, which will negatively impact the frequency response and accuracy of the transducer output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eWhat is the purpose of the connector protector?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eThe connector protector provides environmental sealing at the interface between the probe cable and extension cable, preventing fluid ingress and oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eHow should the cable be shielded?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eThe outer jacket and internal shield are factory-integrated. Do not strip or alter the shielding; ensure the entire path remains unbroken back to the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eDoes the cable require thermal insulation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eThe cable is rated for operation up to 177 deg C. It does not require additional insulation unless environmental temperatures exceed this specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eWhat does the -10 VDC target refer to?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eThis is the standard baseline gap voltage for Bently Nevada proximity systems when the probe is at the designed electrical zero position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eCan this cable be hot-swapped?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eThe extension cable is a passive component. While it can be replaced, signal disruption will occur at the monitoring system during the disconnection process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eHow do I confirm the cable is functioning correctly?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eVerify the signal path using a multimeter to ensure continuity and check for correct gap voltage readings during system commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761590957,"sku":"330103-00-16-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-16-10-12-05-proximity-cable-ft1r4l1yavw.jpg?v=1766977036","url":"https:\/\/www.maxwellplc.com\/products\/330103-00-16-10-12-05-bently-nevada-extension-cable-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}