{"product_id":"330103-00-12-10-12-00-bently-nevada-proximity-probes-3300-xl-series","title":"330103-00-12-10-12-00 Bently Nevada Proximity Probes 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-12-10-12-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103-00-12-10-12-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes, operates as a dedicated hardware component for non-contacting displacement measurement within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330103-00-12-10-12-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: 3300 XL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Suffixes define probe length, mounting threads, connector type, and cable armor specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-12-10-12-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 15 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer \/ Oscillator-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRF proximity modulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes eddy-current probe scaling to convert shaft motion into a standard 7.87 V\/mm (200 mV\/mil) output. During commissioning, gap voltage validation against -10 VDC targets is required to ensure the probe tip operates within the linear range of the transducer. The oscillator circuit provides the necessary excitation frequency, while cross-talk suppression is maintained through matched components to ensure channel-to-channel isolation. Rotor dynamics are monitored by tracking the shaft centerline position and vibration amplitude, with electrical performance calibrated to the defined system loop length.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330103-00-12-10-12-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the probe into the threaded housing; ensure the physical gap distance matches the design specification to achieve the target gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use factory-terminated coaxial cabling; ensure all connections are hand-tightened and clean to prevent signal impedance variations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the probe body to the machine frame to establish a consistent ground reference for the eddy-current field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Route all signal cables through grounded metallic conduit to protect against electromagnetic interference in the industrial environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification: Perform a static gap check using a high-impedance voltmeter before machine startup to confirm correct electrical positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 330103 probe compatible with 3300 XL 5 meter or 9 meter systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes, but the system must use the matching oscillator and extension cable length to maintain calibration and accuracy specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe tip gap measured?\u003c\/p\u003e\n\u003cp\u003eA: The gap is measured electrically by reading the voltage at the oscillator output; standard calibration targets a -10 VDC gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe cable be repaired if the insulation is damaged?\u003c\/p\u003e\n\u003cp\u003eA: No, field repair of the coaxial cable is not permitted as it alters the impedance and electrical characteristics of the calibrated transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does material type affect probe sensitivity?\u003c\/p\u003e\n\u003cp\u003eA: Probe sensitivity is calibrated for 4140 steel; other target materials will require a scaling factor adjustment to ensure accurate displacement readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the armor on the cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable armor provides mechanical protection against debris, oil, and potential physical damage in harsh rotating equipment environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this probe without an oscillator?\u003c\/p\u003e\n\u003cp\u003eA: No, the probe is a passive device and requires a matched 3300 XL oscillator to generate the radio-frequency signal and demodulate displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What causes erratic gap voltage readings?\u003c\/p\u003e\n\u003cp\u003eA: Erratic readings are typically caused by loose connections, electrical noise, target material irregularities, or damage to the probe tip and coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should I use thread locking compound on the probe?\u003c\/p\u003e\n\u003cp\u003eA: Avoid using thread locking compounds or excessive sealant on probe threads to prevent interference with the electrical ground path between the probe and machine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823194797,"sku":"330103-00-12-10-12-00","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-12-10-12-00-3300-xl-8-mm-proximity-probes-wv4fn5zkw02.jpg?v=1766979617","url":"https:\/\/www.maxwellplc.com\/products\/330103-00-12-10-12-00-bently-nevada-proximity-probes-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}