{"product_id":"330101-46-65-10-02-05-bently-nevada-proximity-probes-3300-xl-8-mm","title":"330101-46-65-10-02-05 Bently Nevada Proximity Probes 3300 XL 8 mm","description":"\u003cp\u003eConfigured for non-contact displacement measurement in vibration monitoring architectures, the \u003cstrong\u003eBently Nevada 330101-46-65-10-02-05\u003c\/strong\u003e (\u003cstrong\u003e330101-46-65-10-02-05\u003c\/strong\u003e Proximity Probes) provides direct physical signal execution within machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: 3300 XL 8 mm\u003c\/li\u003e\n\u003cli\u003eThread: 3\/8-24 UNF\u003c\/li\u003e\n\u003cli\u003eUnthreaded Length: 4.6 in\u003c\/li\u003e\n\u003cli\u003eCase Length: 6.5 in\u003c\/li\u003e\n\u003cli\u003eTotal Length: 1.0 meter (3.3 feet)\u003c\/li\u003e\n\u003cli\u003eConnector: Miniature coaxial ClickLoc\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: CSA, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-46-65-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e104 x 1.5 x 1.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Properties\u003c\/h3\u003e\n\u003cp\u003eThe probe facilitates eddy-current probe scaling to convert proximity to conductive targets into linear voltage outputs. Precision performance requires strict gap voltage validation to maintain -10 VDC targets at the center of the linear range. Effective installation must incorporate cross-talk suppression by maintaining specified physical separation between adjacent probes, ensuring that rotor dynamics signals remain free from electromagnetic interference or signal beating caused by proximity to structural components.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e1 x 330101-46-65-10-02-05 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Threaded lock nut\u003c\/li\u003e\n\u003cli\u003e1 x Connector protector\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Thread the probe into the mounting bracket; ensure the jam nut is tightened to prevent axial drift due to machine-induced vibration.\u003c\/li\u003e\n\u003cli\u003eGap Setting: Adjust the probe-to-target gap using a feeler gauge to achieve the nominal gap voltage required by the Proximitor sensor calibration.\u003c\/li\u003e\n\u003cli\u003eGrounding: Maintain electrical isolation between the probe case and the mounting bracket unless the specific installation requires a common ground configuration.\u003c\/li\u003e\n\u003cli\u003eCabling: Secure coaxial cabling at regular intervals to prevent mechanical strain on the ClickLoc connector and minimize exposure to high-temperature gradients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the unthreaded length utilized?\u003c\/p\u003e\n\u003cp\u003eThe 4.6 in unthreaded length allows for deep insertion into machine casings where the mounting bracket is offset from the target measurement surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the Agency Approvals?\u003c\/p\u003e\n\u003cp\u003eThe CSA, ATEX, and IECEx approvals certify the device for safe operation in explosive or hazardous industrial environments; refer to control drawings for installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be used without the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eThe connector is an integral part of the transducer system; removing it will alter the electrical impedance and invalidate the system calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe sensitive to electromagnetic noise?\u003c\/p\u003e\n\u003cp\u003eWhile shielded, the coaxial assembly should be routed away from high-power AC lines to prevent induced noise in the low-level signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat if the gap voltage is outside the -10 VDC target?\u003c\/p\u003e\n\u003cp\u003eA gap voltage shift typically indicates either mechanical movement of the probe or a change in the target material proximity; verify the physical gap immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific extension cable?\u003c\/p\u003e\n\u003cp\u003eThis probe is part of the 3300 XL system and must be mated with a compatible extension cable that matches the total system length requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be used to monitor axial position?\u003c\/p\u003e\n\u003cp\u003eYes, this 8 mm probe is frequently used for axial position (thrust) measurements by monitoring the position of a shaft collar or shoulder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the connector protector?\u003c\/p\u003e\n\u003cp\u003eThe protector prevents moisture, dust, and debris from entering the coaxial connection point, ensuring signal integrity in harsh environmental conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026808557741,"sku":"330101-46-65-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian12_eacb1e33-61c5-4bec-a0a5-7b03080170c7.jpg?v=1781085606","url":"https:\/\/www.maxwellplc.com\/products\/330101-46-65-10-02-05-bently-nevada-proximity-probes-3300-xl-8-mm","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}