{"product_id":"330101-00-46-10-02-05-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-46-10-02-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in 3300 XL machinery monitoring networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-46-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction. This unit captures relative motion between the probe tip and a conductive target, generating an output signal proportional to the gap distance for rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eConfiguration \u0026amp; Suffix Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330101: 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e46: Overall Case Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Type (Miniature coaxial ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency Approval (Multiple approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-46-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Dynamics \u0026amp; Validation\u003c\/h3\u003e\n\u003cp\u003eSystem performance is defined by eddy-current probe scaling, where the transducer operates at a nominal 1 MHz oscillator frequency. Precise gap voltage validation at -10 VDC during machine steady-state operation is necessary to maintain the measurement within the linear range of the Proximitor sensor. To ensure signal integrity and mitigate cross-talk suppression issues, probes must be installed with sufficient physical clearance from neighboring transducers, and coaxial signal paths must be maintained in dedicated, shielded conduit.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-46-10-02-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Best Practices\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the probe such that the tip is perpendicular to the target surface to ensure accurate radial vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten the jam nut using a calibrated torque wrench to prevent mechanical vibration of the probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum 10 mm clearance from the mounting hole wall to prevent side-view interference with the eddy-current field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify all coaxial connections are fully seated in the ClickLoc interface to prevent intermittent signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Index\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used for axial position measurement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3300 XL 8 mm probe is suitable for both radial vibration and axial thrust position measurement on rotating shafts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum acceptable side-view?\u003c\/p\u003e\n\u003cp\u003eA: Ensure at least 10 mm of clearance from the hole wall to avoid non-linear signals caused by peripheral metal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the PPS tip need to be submerged in oil?\u003c\/p\u003e\n\u003cp\u003eA: No, but the PPS material is compatible with immersion in standard turbine lubricating oils and hydraulic fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I test the cable for breaks?\u003c\/p\u003e\n\u003cp\u003eA: Use a digital multimeter to verify impedance and continuity between the center conductor and the outer shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I extend the cable length by adding a splice?\u003c\/p\u003e\n\u003cp\u003eA: No, splicing creates impedance mismatches that alter the signal phase and amplitude, rendering the measurement unreliable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the connector protector?\u003c\/p\u003e\n\u003cp\u003eA: It prevents moisture ingress and physical damage to the coaxial connector threads and coupling interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe intrinsically safe?\u003c\/p\u003e\n\u003cp\u003eA: The probe assembly complies with specific hazardous area classifications when used with approved Zener or galvanic isolation barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the probe detect gap distance?\u003c\/p\u003e\n\u003cp\u003eA: The probe tip coil creates a magnetic field; the proximity of the conductive target absorbs energy, changing the oscillator amplitude.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518836334765,"sku":"330101-00-46-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-46-10-02-05-proximity-probes-4no3vogx24q.jpg?v=1766980046","url":"https:\/\/www.maxwellplc.com\/products\/330101-00-46-10-02-05-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}