{"product_id":"330101-00-20-10-12-05-bently-nevada-3300-xl-series-proximity-probes","title":"330101-00-20-10-12-05 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-20-10-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contacting displacement and vibration measurements across 3500 Machinery Protection System platforms. It transforms micro-level mechanical shaft movements into corresponding electrical voltage variables processed continuously by monitoring hardware units.\u003c\/p\u003e\n\u003ch3\u003eVariable Suffix Arrangement\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option (0.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-20\u003c\/strong\u003e: Overall case length option (2.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Total length option (1.0 m \/ 3.3 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-12\u003c\/strong\u003e: Miniature coaxial clickloc connector with fluid-resistant connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (Multiple hazardous area certifications, ATEX \/ IECEx \/ CSA intrinsic safety)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Parameter Grid\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-20-10-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.5 cm x 17.5 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer component driven by Proximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm transducer architecture relies on precise eddy-current probe scaling to monitor dynamic vibration profiles. Field validation routines demand exact gap voltage validation (-10 VDC targets) representing the definitive geometric center of the linear voltage window. When mapping high-density layouts for multi-plane rotor dynamics analysis, field technicians must adhere to spacing minimums to ensure absolute cross-talk suppression. Unshielded overlapping radio frequency fields between neighboring tips distort the induction curve and corrupt the monitor logic.\u003c\/p\u003e\n\u003ch3\u003eStandard Kit Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330101-00-20-10-12-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Integrated miniature coaxial clickloc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory-installed fluid-resistant connector protector sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation reference guide with certified control drawings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Alignment Checks\u003c\/strong\u003e: Insert and turn the threaded case into the bracket manually to verify clean engagement before finalizing torque via wrenching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Center Setup\u003c\/strong\u003e: Adjust the spatial position of the probe tip relative to the target shaft until the sensor output tracks to -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Field Routing\u003c\/strong\u003e: Protect the 1.0 m coaxial lead inside dedicated steel conduit paths to mitigate abrasion and thermal strain degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Termination Logic\u003c\/strong\u003e: Ground the coaxial outer shield layer strictly at the Proximitor enclosure side to eliminate current leakage across ground networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDispatch and Logistics Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShipping Framework: 2-7 days when payment finish\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistribution Courier: Forwarded globally utilizing premium air freight options through DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Measures: Encased in anti-static industrial packaging configured for drop protection and static shield isolation during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific electrical parameter signifies that the probe gap is correctly calibrated?\u003c\/p\u003e\n\u003cp\u003eThe electrical field calibration requires adjusting the sensor position until the raw DC voltage at the Proximitor reads -10 VDC, securing the exact midpoint of the linear displacement zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe component be hot-swapped while the machinery monitor is under power?\u003c\/p\u003e\n\u003cp\u003eYes, the probe is a passive transducer and can be decoupled from the cable link while live. However, the sudden voltage drop will trigger rack alarms if bypass locks are not set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does targeting alternative metal substrates affect the factory scale factor?\u003c\/p\u003e\n\u003cp\u003eThe internal eddy-current loop is calibrated exclusively for AISI 4140 steel targets. Testing alternative metals changes the magnetic flux properties, introducing significant scaling calculation errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific industrial protection does the -12 option suffix offer the terminal link?\u003c\/p\u003e\n\u003cp\u003eThe -12 option designates a specialized connector protector that encapsulates the clickloc interface, preventing fluid ingress from lubrication oil, moisture, or aggressive chemical vapours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this hardware module draw direct operational current from the monitoring rack backplane?\u003c\/p\u003e\n\u003cp\u003eNo, the probe contains no active electrical components. It acts as a passive reactive load driven entirely by high-frequency excitation voltage generated by the external Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical spacing is mandatory to ensure complete cross-talk suppression between probes?\u003c\/p\u003e\n\u003cp\u003eProbes must maintain a minimum physical distance equivalent to at least three tip diameters from any adjacent probe or unexpected structural metal to preserve magnetic field integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat performance issue occurs if the total cable length is modified outside of specifications?\u003c\/p\u003e\n\u003cp\u003eThe system demands a matching 5.0 m or 9.0 m total system length. Arbitrary cable cutting or extensions throw off the tuned loop impedance, which invalidates the 7.87 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical temperature boundaries governing the probe tip and internal wire?\u003c\/p\u003e\n\u003cp\u003eThe 8 mm tip structure and matching coaxial lead are structurally rated to withstand field conditions ranging from a minimum of -51 deg C up to a maximum limit of +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518849605805,"sku":"330101-00-20-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-20-10-12-05-3300-xl-8-mm-proximity-probes-csgv035qqwj.jpg?v=1766980402","url":"https:\/\/www.maxwellplc.com\/products\/330101-00-20-10-12-05-bently-nevada-3300-xl-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}