{"product_id":"3300-12-02-22-00-bently-nevada-3300-system-power-supply-module","title":"3300\/12-02-22-00 Bently Nevada 3300 System Power Supply Module","description":"\u003cp\u003eConfigured for power distribution in mechanical monitoring systems, the \u003cstrong\u003eBently Nevada 3300\/12-02-22-00\u003c\/strong\u003e (\u003cstrong\u003e3300\/12-02-22-00\u003c\/strong\u003e Power Supply Module) provides direct physical and electrical execution for rack-mounted instrumentation.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3300\/12: Base Model (Power Supply Module)\u003c\/li\u003e\n\u003cli\u003e02: Input Voltage (190-250 VAC, 50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e22: Internal Safety Barrier configuration\u003c\/li\u003e\n\u003cli\u003e00: Not Required (Additional options)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/12-02-22-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 x 20.3 x 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e190-250 VAC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eTo 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/12 power supply module ensures stable DC voltage rails for turbine supervisory instrumentation (TSI). In vibration monitoring racks, maintaining stable power is necessary to ensure eddy-current probe scaling remains within calibration limits. Voltage fluctuations or noise on the supply rail can lead to gap voltage validation errors, specifically causing deviations from the -10 VDC target. Robust internal filtering is provided to minimize noise propagation, ensuring that rotor dynamics data processed by the rack remains free from supply-induced artifacts.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3300\/12-02-22-00 Power Supply Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackplane Seating: Ensure the module is fully inserted and the latching mechanism is engaged to provide a secure connection to the backplane power bus.\u003c\/li\u003e\n\u003cli\u003eInput Wiring: Verify that the AC input voltage matches the specific 190-250 VAC requirements before energizing the rack.\u003c\/li\u003e\n\u003cli\u003eVentilation: Maintain clear air passage above and below the module to allow for heat dissipation within the 3300 rack chassis.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the chassis ground terminal to a common earth ground to ensure personal safety and reduce electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs this module hot-swappable?\u003c\/p\u003e\n\u003cp\u003eThe 3300\/12 module supports hot-swapping; however, ensure the rack configuration is stable before removing or inserting the module during live operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage drops below 190 VAC?\u003c\/p\u003e\n\u003cp\u003eOperating below the rated input range may lead to output instability, trigger fault LEDs, or result in a complete shutdown of the monitored instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module provide redundancy?\u003c\/p\u003e\n\u003cp\u003eThe 3300 system supports redundant power supply configurations; verify that your rack setup includes a secondary module if high availability is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal safety barrier function?\u003c\/p\u003e\n\u003cp\u003eThe internal barrier limits the electrical energy delivered to the field sensors to prevent ignition in hazardous areas, as specified by the module configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this for 110 VAC inputs?\u003c\/p\u003e\n\u003cp\u003eThe -02 option is specified for 190-250 VAC. Using it with 110 VAC is outside the design parameters and will result in insufficient DC output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat do the LED indicators on the front panel represent?\u003c\/p\u003e\n\u003cp\u003eLEDs indicate the status of the AC input, DC output health, and internal fault diagnostics. Refer to the system manual for specific blink codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum load the module can support?\u003c\/p\u003e\n\u003cp\u003eThe capacity is determined by the total number of modules installed in the rack; consult the system power budget spreadsheet for specific load limitations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs periodic calibration required for the power supply?\u003c\/p\u003e\n\u003cp\u003eNo, the module is a fixed-output supply. Regular maintenance should focus on verifying input connections and ensuring the cooling path remains unobstructed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026801905837,"sku":"3300\/12-02-22-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3300-12_2_4.jpg?v=1782792039","url":"https:\/\/www.maxwellplc.com\/products\/3300-12-02-22-00-bently-nevada-3300-system-power-supply-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}