{"product_id":"31000-16-05-00-037-03-02-bently-nevada-proximity-probe-housing","title":"31000-16-05-00-037-03-02 Bently Nevada Proximity Probe Housing","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 31000-16-05-00-037-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e31000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Housing, operates as a dedicated hardware component for mounting and protecting eddy-current transducers within 3300\/3500 Machinery Protection Systems. This housing assembly provides a stable mechanical interface and environmental isolation for proximity probes, ensuring the transducer remains fixed relative to the monitored rotor surface to maintain measurement repeatability.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e31000\u003c\/strong\u003e: Probe Housing assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-16\u003c\/strong\u003e: Mounting thread and pipe size designation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Material and finish specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Approval options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-037\u003c\/strong\u003e: Probe extension\/insertion depth (inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03\u003c\/strong\u003e: Connection and fitting configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Mounting hardware and accessory kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31000-16-05-00-037-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45.0 cm x 15.0 cm x 15.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/A (Passive mechanical component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecified by dash configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-resistant alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Sensor Alignment\u003c\/h3\u003e\n\u003cp\u003eThe performance of proximity transducer systems is contingent upon the rigid mechanical mounting provided by the probe housing. To ensure valid eddy-current probe scaling, the housing must be installed to prevent mechanical resonance or vibration transfer from the machine casing to the probe tip. Precise gap voltage validation at the -10 VDC target depends on the housing's ability to maintain a fixed distance under varying thermal conditions. Proper installation utilizes standard practices for cross-talk suppression by isolating the probe signal path from external electromagnetic interference and ensuring the housing assembly does not introduce spurious motion into the rotor dynamics data.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 31000-16-05-00-037-03-02 Housing assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting locknuts and washers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread sealing components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation instruction manual and alignment reference guide.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Integrity\u003c\/strong\u003e: Ensure the mounting surface is flat and free of debris to prevent misalignment or housing tilt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Specifications\u003c\/strong\u003e: Apply factory-recommended torque to locknuts to prevent loosening due to machinery vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure electrical continuity between the housing and the machine frame for proper shielding of the transducer assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement\u003c\/strong\u003e: Verify the insertion depth matches the required mechanical gap (target: 1.27 mm nominal).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDelivery Information\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipped via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecurely packed in anti-static industrial packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the housing contribute to signal noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA loose or improperly tightened housing allows mechanical vibration to modulate the probe gap, appearing as false vibration in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I prevent fluid leakage through the housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse appropriate NPT thread sealants or O-ring gaskets compatible with the machine's lubricating oil or hydraulic fluid environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the housing compatible with all probe types?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe housing is designed for specific probe diameters (e.g., 8 mm or 5 mm); check the internal bore diameter before attempting to insert a probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I modify the housing length in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModifying the housing length is not recommended, as it alters the insertion depth and may prevent the probe from reaching the specified measurement gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat material is the housing made from?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe housing is constructed from high-strength, corrosion-resistant alloy to withstand harsh industrial environments and prevent seizing in the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the housing require periodic maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect housing locknuts for tightness during regular machine outages to ensure vibration does not cause the housing to back out of the mount.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the probe depth adjusted within the housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe is positioned by rotating it within the housing threads and securing it with the provided locknuts once the target gap is achieved.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the housing grounded to the machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the housing must maintain a reliable electrical connection to the machine frame to ensure the probe cable shield remains at earth potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518841217197,"sku":"31000-16-05-00-036-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-31000-16-05-00-037-03-02-proximity-probe-housingassemblies-kazl0ph2qma.jpg?v=1766980238","url":"https:\/\/www.maxwellplc.com\/products\/31000-16-05-00-037-03-02-bently-nevada-proximity-probe-housing","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}