{"product_id":"2711p-rn6-allen-bradley-panelview-plus-communication-module","title":"2711P-RN6 Allen-Bradley PanelView Plus Communication Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711P-RN6\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2711P-RN6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Module, operates as a dedicated hardware component for Data Highway Plus (DH+), Remote I\/O (RIO), and DH-485 network connectivity within PanelView Plus operator terminal platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix \u0026amp; Physical Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN6 module functions as an expansion adapter mounted to the logic module interface of compatible operator terminals. This hardware supports dual-protocol communication via physically distinct ports: one 3-pin phoenix connector for DH+ and RIO networks, and one 6-pin phoenix connector for DH-485 signaling. This module utilizes passive interface logic to bridge internal terminal bus traffic with external network cabling topologies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711P-RN6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.20 x 12.80 x 4.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerived from backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDH+, RIO, DH-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-pin (DH+\/RIO), 6-pin (DH-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Communication Attributes\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN6 adheres to Allen-Bradley backplane bus communication velocity requirements for legacy operator terminal integration. The module supports Profinet or EtherNet\/IP deterministic network environments indirectly via terminal software configuration. Firmware flash compatibility is handled through the host terminal’s logic module, ensuring that protocol drivers remain consistent with the installed terminal firmware version. The module supports daisy-chain topologies requiring Belden 1770-CD (Blue Hose) for DH+\/RIO and Belden 3106A or 9842 for DH-485 networks to maintain signal integrity over long-distance cable runs.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2711P-RN6 communication adapter module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhoenix terminal block connectors (pre-installed).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting screws for secure logic module attachment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation and installation insert.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Cycle: Isolate the operator terminal from the 24 VDC power source before module installation to prevent backplane short-circuiting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlignment: Align the module interface pins with the logic module header carefully to avoid bending contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Fasten all provided retention screws to ensure a rigid mechanical connection to the terminal housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the DH+ shield drain is terminated to the designated ground point on the network cable to prevent EMI coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use appropriate strain relief for all connected network media to avoid mechanical stress on the phoenix connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Shipping\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL\/FEDEX\/UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll modules are secured in anti-static industrial packaging to prevent electrostatic discharge damage during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes unstable gap voltage?\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RN6 does not provide gap voltage measurements; this query is irrelevant to the communication module’s operational scope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is probe health tested?\u003c\/p\u003e\n\u003cp\u003eThe module performs internal self-tests during power-up; a solid red LED indicates a failed self-test sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe operate in hazardous environments?\u003c\/p\u003e\n\u003cp\u003eInstallation in hazardous environments requires proper enclosure rating; do not connect or disconnect cables while energized to avoid electrical arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat extension cables are compatible?\u003c\/p\u003e\n\u003cp\u003eStandard Belden Blue Hose (1770-CD) is required for DH+ protocols to maintain impedance matching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is module health verified?\u003c\/p\u003e\n\u003cp\u003eModule health is monitored via the two LED indicators; solid green signifies the device is online and receiving a network token.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the expected service life?\u003c\/p\u003e\n\u003cp\u003eThe module is a solid-state passive interface device designed for standard industrial control lifecycles when operated within specified thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066473173165,"sku":"2711P-RN6","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711P-RN6-1.jpg?v=1781064029","url":"https:\/\/www.maxwellplc.com\/products\/2711p-rn6-allen-bradley-panelview-plus-communication-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}