{"product_id":"2711p-rn10c-allen-bradley-panelview-plus-devicenet-communication-module","title":"2711P-RN10C Allen-Bradley PanelView Plus DeviceNet Communication Module","description":"\u003cp\u003eConfigured for DeviceNet fieldbus connectivity in PanelView Plus HMI platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711P-RN10C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e2711PRN10C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Module) provides direct physical\/electrical execution of data exchange between the terminal and the DeviceNet network.\u003c\/p\u003e\n\u003ch3\u003eModel Series Identification\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RN10C is a dedicated communication expansion module specifically designed for the PanelView Plus 400 and 600 terminal series. It enables the HMI to act as a node on a DeviceNet network, facilitating cyclic data exchange with controllers and other networked field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711P-RN10C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg (estimated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 x 12 x 5 cm (estimated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerived from HMI terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanelView Plus 400\/600 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAllen-Bradley Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThis module utilizes the internal expansion port of the PanelView Plus terminal to interface with industrial networks. It supports EtherNet\/IP and DeviceNet deterministic network protocols, ensuring that control data transfer remains consistent with scan-cycle requirements. Firmware flash compatibility between the module and the host terminal's operating system must be verified during initial commissioning to ensure robust communication link stability.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllen-Bradley 2711P-RN10C Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation mounting hardware (screws)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: DeviceNet trunk-line drop cables and 5-pin terminal connectors are not included in the standard module package and must be acquired based on field network topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePre-Installation: Ensure the PanelView Plus terminal is disconnected from all power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Align the module with the communication expansion port on the rear of the terminal. Secure the module using the provided mounting fasteners to ensure proper electrical contact with the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain a continuous path to earth ground for the DeviceNet cable shield at the power supply or network tap to minimize signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Keep signal cabling separate from high-voltage AC paths to prevent induced noise in the DeviceNet differential signal pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are secured in anti-static industrial packaging to provide shock absorption and protection against electrostatic discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the probe operate in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module is rated for standard industrial control panels and is not certified for installation in hazardous (Ex) areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is engineered for long-term continuous operation within the specified temperature limits of the host PanelView Plus terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module requires the host HMI to be powered down before installation or removal to prevent potential damage to the internal backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module health tested?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModule health is verified through the HMI terminal's internal diagnostic screens, which display link status and communication error counts on the DeviceNet network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cables are compatible?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires standard 5-pin DeviceNet shielded twisted-pair cabling for connection to the network trunk line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066473074861,"sku":"2711P-RN10C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711P-RN10C-1.jpg?v=1780394084","url":"https:\/\/www.maxwellplc.com\/products\/2711p-rn10c-allen-bradley-panelview-plus-devicenet-communication-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}