{"product_id":"2711p-rdb12c-allen-bradley-panelview-plus-display-module","title":"2711P-RDB12C Allen-Bradley PanelView Plus Display Module","description":"\u003cp\u003eConfigured for high-resolution visual interface execution in PanelView Plus 1250 platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711P-RDB12C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e2711PRDB12C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDisplay Module) provides direct physical execution of graphical operator feedback and touch\/keypad input processing.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration and Display Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RDB12C is a 12.1-inch color active-matrix thin-film transistor (TFT) liquid crystal display (LCD). It supports 800 x 600 pixel resolution with 18-bit color graphics, facilitating clear process status monitoring and operator interaction via the integrated touch and keypad interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711P-RDB12C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.66 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 x 5.5 x 33 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHost Terminal Dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.1 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 x 600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLuminance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 cd\/m2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKeypad \/ Touch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe display module is engineered for integration within EtherNet\/IP and ControlNet deterministic networks when paired with PanelView Plus 1250 and PanelView Plus 6 1250 terminals. Firmware flash compatibility between the module and the host terminal’s operating system is required to maintain synchronization and I\/O data alignment. Users should verify firmware revisions to ensure stable communication link behavior and high-speed graphical refresh rates.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllen-Bradley 2711P-RDB12C Display Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel mounting fasteners and sealing gasket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical instruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: This module is intended as a component-level replacement and does not include the terminal communication logic processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDe-energization: Ensure the host terminal is isolated from all power sources before proceeding with installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Sealing: Secure the module using the provided fasteners to ensure that the gasket maintains the terminal's specified IP ingress protection rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Seating: Carefully align the internal interface ribbon cable with the logic board connector to prevent pin damage or improper signal termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMI Mitigation: Keep internal signal wiring separated from high-voltage AC paths to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Handling\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShipment via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAll units are protected by anti-static industrial packaging to prevent electrostatic discharge damage and ensure mechanical stability during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should calibration be verified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTouchscreen calibration should be performed whenever input registration drifts from the visual coordinate grid, accessed via the terminal configuration menu.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module operate in hazardous environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis HMI display module is rated for standard industrial control panels and is not certified for installation in hazardous (Ex) zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable display performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePerformance degradation is often attributed to firmware mismatches between the display module and the host logic terminal, or inadequate power supply stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is display health tested?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDisplay health is monitored via the host terminal's built-in self-diagnostic routines during the system boot sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Installation or replacement requires a full power-down cycle of the host HMI terminal to ensure electrical safety and hardware integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066472845485,"sku":"2711P-RDB12C","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711P-RDB12C-1.jpg?v=1780394585","url":"https:\/\/www.maxwellplc.com\/products\/2711p-rdb12c-allen-bradley-panelview-plus-display-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}