{"product_id":"22b-d010n104-allen-bradley-powerflex-40-ac-drive","title":"22B-D010N104 Allen-Bradley PowerFlex 40 AC Drive","description":"\u003cp\u003eConfigured for variable frequency motor control in industrial drive platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 22B-D010N104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e22BD010N104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical and electrical execution of three-phase induction motor speed regulation.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 22B-D010N104 identifies a specific hardware configuration within the PowerFlex 40 product family. The model designation denotes a 4 kW (5 HP) output capacity, optimized for operation on 460 VAC three-phase input supplies, facilitating standard induction motor control across various industrial applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22B-D010N104 \/ 22BD010N104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.88 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 x 13.2 x 18 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kW (5 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase, 460 VAC, 48-63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-400 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Drive Control Attributes\u003c\/h3\u003e\n\u003cp\u003eThe unit utilizes internal firmware for parameter-based motor control. Deterministic execution is supported via communication interfaces allowing for network integration. The drive design includes firmware flash compatibility to support updates to control algorithms and I\/O logic, maintaining compatibility with evolving EtherNet\/IP or other fieldbus deterministic network topologies often used in coordinated drive systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 22B-D010N104 AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x User Terminal Block set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation Instruction Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Stability:\u003c\/p\u003e\n\u003cp\u003eInstall the drive in a vertical orientation on a flat, non-combustible surface to ensure proper heat sink airflow and thermal dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Segregation:\u003c\/p\u003e\n\u003cp\u003eRoute low-voltage control signals and high-voltage power cables in separate conduits to mitigate electromagnetic interference coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Requirements:\u003c\/p\u003e\n\u003cp\u003eEnsure the drive chassis is connected to a common earth ground using a low-impedance conductor to minimize noise and maintain system reference potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVentilation Clearance:\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum of 10 cm of free space above and below the drive unit to facilitate convective cooling during peak load operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this drive be hot-swapped while energized?\u003c\/p\u003e\n\u003cp\u003eNo. The input power must be disconnected and the DC bus capacitors must be allowed to discharge completely before any physical extraction or terminal access occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the drive support firmware updates?\u003c\/p\u003e\n\u003cp\u003eYes. The controller supports firmware flash compatibility, allowing users to update internal control algorithms via the serial port or communication option module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the output frequency adjustable during operation?\u003c\/p\u003e\n\u003cp\u003eYes. The output frequency can be modified in real-time via the integrated keypad or external reference signals (e.g., 0-10 VDC or 4-20 mA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of exceeding the output current limit?\u003c\/p\u003e\n\u003cp\u003eThe drive will initiate a hardware-level overcurrent trip and disable the output transistors to prevent damage to the inverter bridge or the connected motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit operate with a single-phase input?\u003c\/p\u003e\n\u003cp\u003eNo. The 22B-D010N104 model is specifically designed for three-phase input power; using single-phase input will result in undervoltage faults or bridge damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal parameters retained if power is lost?\u003c\/p\u003e\n\u003cp\u003eYes. All programmed configurations and motor parameters are stored in non-volatile memory (EEPROM) and remain intact during power cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the required torque for terminal screws?\u003c\/p\u003e\n\u003cp\u003eRefer to the drive housing label for specific torque values; generally, ensure a firm connection to prevent high-resistance contact points which cause localized heating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the drive have integrated bypass capability?\u003c\/p\u003e\n\u003cp\u003eNo. This model is a standard VFD; an external bypass contactor circuit is required if a fail-safe across-the-line start capability is necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066470879405,"sku":"22B-D010N104","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/22B-D010N104-1.jpg?v=1782294013","url":"https:\/\/www.maxwellplc.com\/products\/22b-d010n104-allen-bradley-powerflex-40-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}