{"product_id":"2198-h070-ers2-allen-bradley-servo-drive-kinetix-5500","title":"2198-H070-ERS2 Allen-Bradley Servo Drive Kinetix 5500","description":"\u003cp\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb class=\"\"\u003eAllen-Bradley 2198-H070-ERS2\u003c\/b\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e also cataloged as the \u003c\/span\u003e\u003cb class=\"\"\u003e2198-H070-ERS2\u003c\/b\u003e\u003cspan class=\"\"\u003e Servo Drive,\u003c\/span\u003e\u003cspan class=\"\"\u003e operates as a dedicated hardware component for closed-loop motor positioning and safe torque execution within EtherNet\/IP Network architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eModel Suffix Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb class=\"\"\u003e2198\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Kinetix modular drive system series identifier.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb class=\"\"\u003eH070\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Frame size 3 drive rating providing 11.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 A continuous current output.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb class=\"\"\u003eE\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Dual Ethernet communication interface supporting CIP Motion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb class=\"\"\u003eR\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated Device Level Ring (DLR) network redundancy protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb class=\"\"\u003eS2\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Networked Safe Torque Off (STO) functional safety execution level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eHardware Performance Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2198-H070-ERS2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.6 cm x 8.1 cm x 25.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 W control power (drive logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMain Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190 to 528 VAC 3-phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.3 A (0-peak)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeak Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.3 A (0-peak)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 kW at 230 VAC \/ 7.0 kW at 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eEtherNet\/IP Deterministic Synchronization and Flash Execution\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe drive leverages EtherNet\/IP deterministic networks to process real-time CIP Motion trajectory commands alongside hard-real-time CIP Safety signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e Internal control loops calculate high-bandwidth current and velocity vectors synchronized with central automation controllers.\u003c\/span\u003e\u003cspan class=\"\"\u003e Firmware flash compatibility maintains drive operating parameters,\u003c\/span\u003e\u003cspan class=\"\"\u003e motor feedback profiles,\u003c\/span\u003e\u003cspan class=\"\"\u003e and network configurations in non-volatile flash memory to protect data integrity during system shutdown cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e1 x Allen-Bradley 2198-H070-ERS2 Servo Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e1 x Shared AC\/DC Bus Connector Plug Set\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e1 x Motor Power and Feedback Terminal Plug Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePhysical Cabinet Installation Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThermal Ventilation Gap Mount the unit vertically on a metallic backplate maintaining 100 mm top and bottom clearance for natural convection cooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDirect PE Grounding Bond the drive enclosure ground lug directly to the cabinet protective earth (PE) bus bar using a low-impedance copper strap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eShielded Cable Termination Terminate motor power cable braided shields directly to the chassis grounding plate using heavy-duty 360-degree clamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eShared Bus Interconnection Align adjacent Kinetix 5500 drives using original shared AC\/DC bus bars to eliminate discrete power wiring connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eTerminal Plug Tightening Torque all removable power terminal block screws to a maximum specification of 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 Nm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eHardware Technical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eWhat continuous current rating does the 2198-H070-ERS2 output to connected servo motors?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe drive delivers up to 11.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 A continuous current (0-peak) and 28.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 A peak current across three-phase AC output phases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDoes the 2198-H070-ERS2 drive support hot-swapping under active line voltage?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eHot-swapping is prohibited; line power and 24 VDC control power must be completely isolated before removing power connector blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eHow does the network safety function execute over the Ethernet interface?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eSafety logic processes hard-real-time Safe Torque Off (STO) commands transmitted directly via CIP Safety over EtherNet\/IP protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"animating\"\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"\"\u003eWhat control voltage input is required to energize internal drive logic?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"\"\u003eThe internal control circuitry requires an external regulated auxiliary power source supplying 24 VDC at 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e63 A continuous load.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"animating\"\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"\"\u003eWhat physical feedback types connect to the motor feedback connector?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"\"\u003eThe drive supports Hiperface DSL single-cable technology along with digital quadrature feedback encoders via dedicated terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhat topology modes are supported by the dual RJ45 Ethernet interfaces?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe dual ports support linear,\u003c\/span\u003e\u003cspan\u003e star,\u003c\/span\u003e\u003cspan\u003e and Device Level Ring (DLR) fault-tolerant network topology configurations natively.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the upper operating temperature limit without thermal derating?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe drive functions at full rated capacity from 0 deg C up to 50 deg C ambient panel temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhich software package handles drive configuration and motion axis tuning?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDrive parameters,\u003c\/span\u003e\u003cspan\u003e axis setup,\u003c\/span\u003e\u003cspan\u003e and gain tuning are configured using the Studio 5000 Logix Designer application environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47240372093101,"sku":"2198-H070-ERS2","price":1099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_2198-h070-ers2_1.jpg?v=1787030716","url":"https:\/\/www.maxwellplc.com\/products\/2198-h070-ers2-allen-bradley-servo-drive-kinetix-5500","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}