{"product_id":"21747-075-01-bently-nevada-proximity-probe-extension-cable-7200-series","title":"21747-075-01 Bently Nevada Proximity Probe Extension Cable 7200 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 21747-075-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e21747\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Extension Cable, operates as a dedicated hardware component for transmitting high-frequency RF signals between a proximity probe and a Proximitor Sensor within 7200 Series machinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21747-075-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 22.0 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive RF transmission element (zero power consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 meters (approx. 24.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard stainless steel flexible armor (-01 configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 ohms nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 21747-075-01 extension cable provides the precise electrical electrical impedance and capacitance parameters necessary to complete the resonant tank circuit of a 7200 Series 5 mm or 8 mm proximity transducer system. Proper cable length matching directly impacts eddy-current probe scaling. Any deviation in total system length (combining probe lead and extension cable to match the calibrated 5.0-meter or 9.0-meter Proximitor requirement) will shift the factory scale factor of 7.87 V\/mm (200 mV\/mil). During field calibration, accurate loop matching allows for strict gap voltage validation (-10 VDC targets), ensuring the transducer operates within its linear range to precisely monitor rotor dynamics and prevent cross-talk suppression failures on adjacent machine channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMechanical routing of armored coaxial extension cables requires adherence to bend radius limits. The minimum bend radius for the stainless steel armored cable is 25.4 mm (1.0 in). Avoid executing sharp angles or crimping the outer armor, as structural distortion changes internal coaxial capacitance and compromises signal tuning. Route the cable through dedicated, isolated low-voltage instrument trays to ensure optimal cross-talk suppression from nearby high-current lines. Coaxial connectors must be dry and free of particulate contamination prior to mating. Thread the miniature coaxial connectors together tightly by hand, and slide the specified connector insulation sleeves over the junction to prevent ground loops caused by contact with local machine housings. The entire sensor circuit must maintain an isolated ground profile up to the monitor backplane termination block.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can a 7.5-meter extension cable be paired with a 1.0-meter probe lead on a 5.0-meter Proximitor Sensor?\u003c\/p\u003e\n\u003cp\u003eA: No. The total physical and electrical length of the probe lead plus the extension cable must match the exact tuning specifications of the Proximitor Sensor. A 7.5-meter cable matched with a 1.0-meter probe forms a 8.5-meter total length system, which will cause a severe calibration shift and fail gap voltage validation if connected to a 5.0-meter or 9.0-meter rated sensor module.\u003c\/p\u003e\n\u003cp\u003eQ: Does cutting or splicing the 21747-075-01 cable in the field affect calibration?\u003c\/p\u003e\n\u003cp\u003eA: Splicing or changing the physical length of this high-frequency coaxial cable is strictly prohibited. Modifying the cable alters its nominal 95-ohm impedance and total capacitance, invalidating the eddy-current probe scaling and causing the diagnostic circuit to flag a permanent loop failure or \"Not OK\" status at the monitor panel.\u003c\/p\u003e\n\u003cp\u003eQ: What protection does the -01 armor suffix provide against fluid exposure?\u003c\/p\u003e\n\u003cp\u003eA: The stainless steel flexible armor provides mechanical crush protection and abrasion shielding. However, the armor itself is not fluid-tight. For installations exposed to continuous oil splash or corrosive chemical environments, the cable must be routed inside liquid-tight flexible conduit or specified with an optional outer fluoropolymer jacket.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518824439981,"sku":"21747-075-01","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-21747-075-01-proximitor-probe-extension-cable-if20dtivfgx.jpg?v=1766979633","url":"https:\/\/www.maxwellplc.com\/products\/21747-075-01-bently-nevada-proximity-probe-extension-cable-7200-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}